Roof Flashing Flashcards

(17 cards)

1
Q

What is a stack or vent terminal?

A

The outlet of a pipe which equalizes the atmospheric pressure within the plumbing system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Why do we install roof flashing?

A

To prevent water from leaking into the building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is flashing?

A

A piece of sheet material, which is secured to both the pipe and the roof in such a way as to deflect any water flowing onto it

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Name three OBC permissible materials for roof flashing

A

Copper sheet aluminum sheet lead sheet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In the case of a shingled pitched roof, the flashing must be located where

A

Under the shingles on the upper side and on top of the shingles on the downward side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is used to secure the flashing to the roof under the shingles?

A

Roofing nails

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If the vent terminal extends a distance of ____ meters above the roof level, _____ must be installed to secure the terminal against high winds

A

2 meters
Tie down wires

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the size minimum size for a shingle roof flashing?

A

500 mm x 500 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the ways to protect against frost

A

The OBC code recommends that the vent terminal be increased by one pipe diameter above 150 mm or by insulating the pipe
Also a heat tracing cable can be installed
The vent terminal shall be installed higher than the top level of the snow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Roof flashing is installed to ____ water from_____ into the building

A

Prevent
Leaking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The flashing used must be approved by the

A

OBC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The minimum height of any stack terminal is

A

6 inches high

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The flashing is to be installed by the

A

Plumbing contractor, but really roofer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The installation of a flashing must not_______ the stack terminal in anyway

A

Obstruct

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If the roof is flat, the flashing should be______ layers of roofing material, which will then _____ to the flashing

A

Between
Seal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If the vent terminal extends a distance of 2 m above roof level _______ must be installed to secure the vent terminal against

A

Tie down wires
High winds

17
Q

If the stack and vent is installed during temperatures of 80°F, the dome should be compressed approximately ______ before waterproofing joint is completed to the pipe in order to allow for movement