Rules And Regulations Flashcards

(37 cards)

1
Q

All scaffolds and ladders must have _ on bottom of them

A

Base plates

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Ensure level and plumb, max?

A

1/2” every 10’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Ensure scaffold is tied off,
what rule?
Every _
Height intervals?
Length

A

3:1 rule
5’
15’ height
20’ length

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What should you do with clamps attached to scaffolds?

A

Inspect and tighten if appear loose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Ensure height clearance is?

A

6’6”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the ledger spacing max?

A

6’6” same as height clearance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

All transoms must be supported no more than?

A

5’ intervals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Ensure a what brace is installed at base? And cross bracing no more than?

A

Clam/X/plan brace
15’ intervals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Ensure ledgers are connected to standards with what clamp only?

A

90/right angle clamp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

All diagonal bracing must be supported at _ intervals unless noted on _ drawings

A

10’
Engineed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Joiners must have ledger tube within _ above and below, scaffolds with joiners must have diagonal _

A

1’
Bracing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Joiners on ledgers (avoid if possible) can lossen with weight overtime and collapse, if you can’t make sure to have supported by solid _ above and below at _ or the node point (standard)

A

Tube
6”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Transoms mounted on ledgers must be _ of the standard or _ point

A

6”
Node

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Diagonal bracing is installed between _ to _ • _ is the usual number

A

Between 30-60 degrees 45 is the usual

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What’s is correct scaffold platform height for work?

A

3’-5’ below work

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Access to scaffold and scaffold platforms should be?

A

Clear and unobstructed

17
Q

Scaffold access should be minimum of _

A

22” opening

18
Q

Describe swing gate install

A

Self closing
36-42” above work platform
Swings away from ladder

19
Q

If swing gate can not be installed what should you use in place of?
And what do you do after installing of them?

A

Double chain gate
Note on tag

20
Q

Ladders should have _ toe clearance

21
Q

Ladders should extend _ or _ of work platform

A

36” or 3’

22
Q

Rest deck ladders should be no more than _ between platforms and should be _ of each other

23
Q

Caged ladder requirements
_ square
Horizontal tube guard rails every _
Max spacing.
Vertical guard rail spacing?
From bottom _ height no less then _
Cage has to extend _ past platform
Max ladder height _
_ required on all ladders

A

28-30”
4’
14-15”
7’2” max no less then 6’6”
36” or 3’
30’
Baseplates

24
Q

Ensure planks can’t move _ or _

A

Vertical and horizontal

25
Planks can’t extend more than _
7’
26
Ensure _ clearance from none structural items
1”
27
Aluminum filler plank doesn’t exceed _ space and should be supported by _ at both ends
5” Transom
28
No more than _ wide of aluminum planks are supported by planks on both sides spanning full length of deck
19”
29
Transom connected to aluminum planks extent beyond double bolt connecter _ past
4”
30
Toe bored height is _
5”
31
What should not be at the access of platforms?
Toe bored
32
Aluminum toe board should be secured with _
Toe bored clips or clamps
33
Deck must be _ for defects
Inspected
34
Handrail/ guard rail must be at Midrail height?
36” and 42” Mid way between handrail and platform
35
Any hazard or deviation should be _
Noted on tag
36
Scaffold tag should be updated _
Monthly
37
Scaffold plank should extent a minimum of _ past the standard the max is _
6” 9”