SCBA Flashcards

1
Q

Face Piece/Mask

A

-G1 Face piece
- SpeeD-ON Kevlar 5 point harness
-No electronics on the face piece itself
-NFPA compliant heat protect to 500 degrees for 5 mins and Flame impingement for 10 secs
-Lens view of 86% and overlapping view of 122%
-Inhalation check valve
-Exhalation valve in face piece
- Open port design

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Heads up display for Face Face Piece and 2nd stage regulator

A

-Right side air management
- 4 Green LED= 75% to 100%
- 3 Green LED= 50% to 74%
- 2 Yellow LED= 36% to 49%
- 1 Red LED= 0 to 35%
-left side provides icons for system status

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

2nd Stage Regulator

A

-Large Buttons on top and bottom to remove regulator and automatically shut off the flow of air
- A true bypass knob for increased during emergency bypass operations- up to 120 PSI
- Dual Microphones
-LED for HUD information
-Regulates120 psi to breathable air at 14.5 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

G1 Speaker Module

A

-Small lightweight and located on left shoulder
-Amplifies speech to 75 dBa
- Hardwired to SCBA
- Automatically turns on by opening cylinder
- Press and hold blue button to turn off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Control Module (integrated PASS)

A
  • Auto activation turns on display when lifted
  • PASS alarm initial alert activates at 18secs
    -shake or press green button to reset
  • Full alarm sounds at 30 secs of motionless
    • both green buttons will need to be
      pressed to reset full alarm
  • Screen color changes based on HUD logic
    -Low battery alarm beeps every 10 secs
    -After 3 minutes of breathing the control module will calculate a time for remaining air, and will update every 30 secs after that
    -Buddy lights- six total lights are viewable 360 degrees and bell in locating firefighter, they provide HUD matching indicators
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Power Module

A

-Main control system
- Air/ water sealed software/ firmware
- PASS integrated
- 100 dBa at 3 meters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Pressure reducer(1st stage regulator)

A

-Regulates HP 4500 PSI to 120 psi
-Burst Disk rated at 7000psi
-Bell Assembly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Cylinders/ bottles

A

-4500 psi/ 45 min bottles/ 66 cubic feet
- Large luminescent band and gague face
- Change bottle when below 4000 psi
- Hydro tested every 5 years
-life span of 15 years
-Quick connect
-Cylinders are wound with high-strength carbon fibers impregnated with epoxy resin. with a over wrap of fiberglass

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Carrier and harness

A

-Drag handles at the top are rated at 1000 lbs
-Side hands rated at 500 lbs each
-Cylinder dovetail connection
-Stainless steel cylinder band
-Cylinder band is fully adjustable for different size cylinders
-Adjustable lumbar pad with three different positions
-Kevlar reflective metal buckles
-Harness is standard Nylon and -Kevlar with nanosphere coating to reduce moisture ingress

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Central Power supply

A

-Powers all lights, communications and controls from one source
- Battery type- Li-Ion(Rechargeable Battery)
-Avg life between 3-8 weeks
-charging time 4-6 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly