Section 2 URE Flashcards
(50 cards)
On the type III hydrant system, which filter separator control valve function will prevent the elements from bursting and allowing contaminated fuel downstream?
Maximum DP shutoff
On the type III hydrant system, what will make the automatic bypass valve open and let fuel bypass the filter separator when receiving cross-country pipeline?
DP of 20 psi sensed across the receiving filter separator
On the type III hydrant system, the ball float assembly for the high-level shutoff valve is located on an aboveground operating storage tank on the
Exterior of the tank at the required shut-off height
If the tank outlet Manual valve on the type III hydrant system is open during an emergency stop situation, the
Horn will sound
When the PRT on the type III hydrant system is 70 percent full, the
Switch assembly automatically turns on the pump
How long will the fueling pumps on the type III hydrant system operate if the control circuit is not closed and what component closes the circuit?
5seconds; flow switch
To what component is the DPT on the type III hydrant system connect?
Venturi
Where does the type III hydrant system PIT sense atmospheric pressure?
Issue line
How many differential pressure transmitters are installed on the issue line of the type III hydrant system with a refueling capability of more than 2400 gallons per minutes
Four
On the type III hydrant system what size is the hydrant control valve that is designed for a flow rate of 600 gallons per minute
4 inches
The back pressure control valve in the type III hydrant system will close at what hydrant loop flow rate?
600 gpm
On the type III hydrant system how many DPTs are connected to the 4 inch return Venturi?
4
What type III hydrant system component is flush mounted on the end wall of the pump control panel, is completely solid state with no moving parts and indicates an emergency is occurring?
Alarm annunciator
Which condition will cause the vibrating horn to sound on the type III hydrant system?
System engine generator default
The purpose of the lock out key used on the type III hydrant system is to
Transfer control from one microprocessor to the other
How many days minimum can the battery in the type III hydrant system maintain the microprocessor’s memory
30
On the type III hydrant system, the LED in the battery backup system in each microprocessor will indicate a problem at least how many days in advance before the battery becomes weak enough to jeopardize the integrity of the memory
3
What is the rated capacity of the pumps on the type IV hydrant system?
600 gpm
When using the type IV system how many aircraft depending on the type can be hot refueled simultaneously in about 8 to 12 minutes
Two
How many tanks are used with the type IV hydrant system and how many gallons will each hold?
Four; 50,000
On the type IV hydrant system How is fuel prevented from spilling onto the hot pad should a hose separate from the nozzle during a hot refueling operation?
A dry break coupler located inside the hose will close automatically.
Since the type five hydrant system is not required to be manned when it is operated inspections are performed every
3 hours
On the type five hydrant system what size are the stainless steel pantographs installed inside the hardened shelters
3 inches
Who should be contacted if the DD form 250 bill of lading or contractor delivery ticket is not available upon arrival of the tank truck?
Quality assurance representative