studies show flashover can occur at ____ minutes
10
loss of elevators in a high rise fire typically occurs approximately ____ minutes into the operation
20
serious high rise fires require a minimum of ___ handlines
3
strategic operating guidelines for high rise fires
- Locate the fire
- Relocation of occupants or evacuation
- Access, identify, and gain control of the building systems
- Confine and extinguish the fire
- Control extension to floors above
staging in a high rise fire is normally ___ floors below the fire
2
base location is usually located ____ ft or more from the high rise structure fire
200
park apparatus at _____________ to allow easy access and egress in Base
diagonal angles
spare ______________ are always first priority when moving equipment from base to high rise
SCBA air cylinders
_________________ is responsible for the control of fire department personnel and civilians entering and exiting the building.
Lobby Control Unit Leader
______________ should verify that the water supply into the building standpipe system has been completed
lobby control
when evacuating civilians from a high-rise, move occupants a minimum of ______ ft. from the building.
200
_________________ function is implemented when equipment needs to be moved to Staging by stairwells or when an additional water supply is needed.
The Ground Support
Ground Support, consider ___ person per two floors and ___ officer per four or five personnel
1,1
3 companies for each handling in a high-rise fire. 1 company on the handline, one company at the stair shaft landing, and one company in staging.
the relief cycle
for highrise fires, it is essential that the IC be stationed at ____________
ground level
split bank elevators may be used to ascend to fire floor if the highest floor of the elevator shaft is a minimum of ____ floors below the reported fire floor.
5
good rule of thumb when ascending to fire floor via stairwell is to give the IC an update every ____ floors during the ascent
2-3
personnel should never take any elevator, which services all floors, to go ________ the fire
above
high rise is considered anything over ____ ft. or ___ stories tall
75, 6
this type of high rise building is the least likely to collapse under fire conditions
masonry bearing wall high-rise
modern method of constructing high-rise buildings is commonly called _____________
core construction or center core construction
roofs on high rise buildings are required to have at least a ___ hour fire resistive rating
2
shaft enclosures in high rise buildings are required to have a minimum of a ___ hour fire resistive rating
2
floors in high rise buildings are required to have a ___ hour minimum fire resistive rating
2