Test 2 Flashcards

1
Q

what ion parameter is measured in mass spectrometry

A

mass/charge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

what is the source of charge of protein ions in the electrospray ionization method

A

external power supply

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

the role of trypsin used in peptide mass fingerprint measurements is to

A

digest each protein into a defined set of fragments

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

what is measured in nanopore sequencing

A

current flowing through the nanopore

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

sequencing nanopores produced from graphene are typically

A

too wide

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

currently the best sequencing nanopore is made from

A

MspA channel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

the advantage of nanopore sequencing over 1st and 2nd generation sequencing methods is

A

longer read length

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

voltage difference applied across a membrane containing a sequencing nanopore causes flow of the following substances through the nanopore

A

all of the above ( pos ions, neg ions, and DNA)`

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

if the pressure driving the sheath stream in a flow cytometer is decreased the diameter of the sample stream at the interrogation point will

A

increase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

measurements of light scattering in the forward direction reflect cell

A

size

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

measurements of light scattering in the side direction reflect cell

A

granularity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

what dichroic mirror is required to combine 2 laser beams as shown in the figure(633 nm and 488 nm)

A

LP 600 nm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

in FACS drops are formed because of

A

nozzle vibration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

the role of the ion mirror in time-of-flight mass analyzer

A

increase differences in path lengths traveled by ions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

if accelerating voltage in the time-of-flight mass analyzer is 30kV what should be the voltage in the ion mirror

A

32kV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

the diameter of a sequencing nanopore has to be approximately equal to

A

diameter of a single-stranded DNA molecule

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

the length of a sequencing nanopore has to be approximately equal to

A

distance between nucleotides in a single-stranded DNA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

the most important limitation of the approach that employs a native membrane channel as a sequencing nanopore is

A

DNA translocation is too fast

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

deflection of drops in FACS is caused by

A

electrical force

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

photon energy is proportional to the light wave

A

frequency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

fluorophore molecules

A

absorb and emit light of a longer wavelength

22
Q

the diagram shows energy levels(jablonski diagrams) of two fluorophores which fluorophore has longer peak emission wavelength

A

A bc lines are closer

23
Q

in a flow cytometer the transmission band of the emission filter should overlap with

A

fluorophore emission spectrum

24
Q

non-specific dna dyes are used to stain cell

25
the diagram shows energy levels (jablonski diagrams) for two organic fluorophores which fluorophore has larger dimensions of the fluorescent part of the molecule
A bc lines are closer
26
the plot shows spectra of voltage sensitive dye di-4-anepps what is the approximate value of the dye stokes shift (peak one at 450 nm and 650 nm peak)
200 nm
27
what should be the approximate transmission range of an optical filter suitable for measurement of fluorescent emission of di-4-anepps
650/50 nm
28
what is the cause of fluorophore photobleaching
interaction of excited fluorophore with surrounding molecules
29
what methods can potentially help reduce phototoxicity of organic fluorophores
remove oxygen and change excitation filter
30
both graphene sequencing nanopores and alpha hemolysin channel sequencing nanopores are limited by
DNA translocation is too fast
31
which ion parameter is measured in mass spectrometry
none of the above( momentum, mass, charge, energy)
32
which parameter is measured by mass spectrometry
the mass/charge ratio
33
what is the source of charge of protein molecules in the MALDI ionization method
Matrix
34
in a time of flight mass analyzer
lighter ions will arrive to the detector first
35
what is the purpose of the first mass spectrometer in the tandem mass spectrometry
select a peptide
36
what is the purpose of the second mass spectrometer in the tandem mass spectrometry
measure mass of peptide fragments
37
trypsin is used in mass spectrometry because
it digests each protein into fragments
38
photon energy is proportional to the light wave
frequency
39
the frequency of the emitted fluorescent light in comparison to the absorbed light is
smaller
40
which ion parameter is changed when an ion mirror is added to a time of flight mass analyzer
ion path length
41
fluorescent dye molecules for staining mitochondria are electrically
positive
42
generic (non-specific) DNA fluorescent dye molecules are electrically
positive
43
DNA staining with generic fluorescent dyes can be performed
in live or dead cells
44
non specific fluorescent DNA dyres are typically used to stain
Nucleus
45
immunoflourescent probes may include
small organic fluorophores, quantum dots, proteins
46
in comparison to organic fluorophores quantum dots are likely to have
stronger long-term chemical toxicity
47
the emission spectrum of a quantum dot in comparison to a typical organic fluorophore is
narrower
48
the absorption spectrum of a quantum dot in comparison to a typical organic fluorophore is
wider
49
a decrease of quantum dot diameter will have the following effect on the wavelength of it fluorescence emission
decrease
50
which fluorophores are membrane permeable(may diffuse passively through membrane)
none (all fluorophores can be used on fixed cells that have been made permeable)
51
what happens when quantum dot diameter increases
the energy levels get smaller meaning the wavelength gets bigger with increasing diameter of the quantum do