Test 3 Multiple Choice Flashcards

(35 cards)

1
Q

Oxygen and other noncondensable gases are separated from the feedwater______

In the closed feedwater heater

In the economizer

In the open dearator feedwater heater

A

In the open deaerator feedwater heater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Steam is extracted from the turbine after it has passed through some of the turbine stages to

Reduce back pressure

Increase back pressure

Prevent excessive speed withing the turbine

Be used for process work in the plant

A

Be used for process work in the plant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A surface condenser has water____.

And steam mixed together to create a vacuum

Passed through tubes to cause steam to condensate causing a vacuum

A

Passed through tubes to cause steam to condensate causing a vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

A draft fan located between the boiler and chimney is used in a ______ draft system

Natural

Forced

Induced

Furnace induction

A

Induced

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When steam is superheated it has_______

A higher pressure thus producing more power

A large volume

More heat energy thus producing more work

A higher temperature and pressure

A

More heat energy thus producing more work

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A vacuum on the exhaust side of the turbine

Reduce back pressure and steam flow rate

Reduce back pressure and increase water rate

Prevents excessive speed withing the turbine

Vacuum is never allowed on the turbine

A

Reduces back pressure and steam flow rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The open feedwater heater is located

Above the feedwater pump

Below the feedwater pump

After the closed feedwater heater

A

Above the feedwater pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Draft is defined as a difference in pressure that causes.

Air or gases to flow

A balance of pressure

A back pressure

A

Air or gases to flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Air is mixed inside of the burner register in a_______gas system

Low pressure

High pressure

Equalizing

Fuel oil

A

High pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Gas leak should be located and repaired by a. ______

Boiler operator

Shift foreman

Fuel superintendent

Gas company representative

A

Gas company representative

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Water weights approximately_____lb/gal

2

  1. 4
  2. 3

10

A

8.3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A______ pump returns condensate from the system back to the boiler

Fuel oil

Return

Gear

Vacuum

A

Vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The feedwater ______ valve opens and closes automatically

Return

Bypass

Check

Equalizing

A

Check

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

An auxiliary low water fuel cutoff is installed

Slightly above the NOWL

Slightly below the primary low water fuel cutoff

At the highest point on the boiler

A

Slightly below the primary low water fuel cutoff

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The______ maintain a constant water level in the boiler

Gauge glass

Water column

Blowdown tank

Feedwater regulator

A

Feedwater regulator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The low water fuel cutoff should be tested_____

Daily

Monthly

Semiannually

Annually

17
Q

A______valve controls fluid flow by turning the valve handle to raise or lower the valve disc

Safety

Pressure relief

Glove

Backflow preventer

18
Q

The most common feedwater pump is a____feedwater pump driven by an electric motor

Steam rotary

Generator

Centrifugal

Piston activated

19
Q

The purpose of the feedwater regulator is to________

Shut the boiler in the event of low water

Maintain a consistent water level in the boiler

A

Maintain a consistent water level in the boiler

20
Q

The automatic makeup water feeder is located

Slightly below the NOWL

On the feedwater heater

A

Slightly below the NOWL

21
Q

Feedwater regulator sensing elements are located

On the steam line

On the water line

At the NOWL

22
Q

Water temperature that is too low in the open feewater heater could cause____

Oxygen pitting in the boiler

Thermal shock in the boiler

A

Oxygen pitting in the boiler

23
Q

Burning a fuel releases_____

Solar energy

Hydrogen gas

Heat energy

24
Q

A vent line on a fuel oil tank prevents____

Loss of suction

Pressure buildup

Loss of pressure

A

Pressure buildup

25
A high suction line on a fuel oil tank is used when_____ The tank is full The tank is low on fuel Signs of sludge and water are evident in the tank
Signs of sludge and water are evident in the tank
26
The pneumercartor is used to_____ Indicate the fuel oil level in the tank Supply primary air to the burner Indicate gallons of makeup water used
Indicate the fuel oil level in the tank
27
An indication of a dirty fuel oil strainer would be_______across the strainer A large pressure drop An equalizing of pressure A slight pressure drop No change in pressure
A large pressure drop
28
Fuel oil heaters must be protected from excessive fuel oil pressure because they are located______in the pumps Above On the suction side On the discharge side They need no protection due to control line
On the discharge side
29
A gas pressure regulator is used to control the______ Flow of gases of combustion Desired set pressure at the burner Air flow going to the burner Mixture of air and gases
Desired set pressure at the burner
30
To prevent caking and to dry the coal entering the pulverizer Heating coils are used Electric pipe heaters are used Warm air is used Dryers are used
Warm air is used
31
Blowers are used in a high pressure gas system to_____ Supply air for combustion Remove gases of combustion Regulate the flow of gas Cool the combustion chamber
Supply air for combustion
32
The gas pressure regulator in the low pressure gas system reduces the gas pressure to______psi 0 5 10 16
0
33
The amount of gas drawn into the air stream in a low pressure gas system is controlled by the______ Manual reset valve Check valve Venturi effect Flow control calve
Venturi effect
34
The underfeed stoker can burn Only anthracite coal Only bituminous coal Anthracite or bituminous coal
Anthracite or bituminous coal
35
The thickness of the fuel bed on a chain grate stocker is regulated by a coal____ Conveyor Scale Hopper Gate
Gate