Tool Specs Flashcards
Holmatro battery info
Lithium-Ion PBPA287
Fully charged battery is approx 40 cuts/spreads
3.3 lbs
Volts 28 VDC
Onboard holmatro battery charger
“On tool charging” priority given to battery on tool first. When battery reaches 100%, automatically changes to charge battery on charger.
Average charge time 205 minutes
Fluid used for holmatro tools
Nontoxic mineral oil
Battery powered holmatro spreaders specs
PSP 40 (Pentheon Spreader)
Weighs 42.75 lbs
Spreads 28.5 inches
Max spread force 63,000 lbs
Max pull force 11,600 lbs
Max squeeze force 13,200 lbs
Battery powered holmatro cutter specs
PCU 50 cutter (pentheon cutter)
Weighs 47.39 lbs
Max cutting opening 7 1/8 in
Cutting force 312,247 lbs
Battery powered holmatro telescoping ram specs
PTR 50 telescoping ram
Weighs 43.87 lbs
Retraction length 22 3/4 in
Spread stroke 1st plunger 16 in
Spread stroke 2nd plunger 15 in
Max length extended 53 3/4 in
Spread force 1st plunger 30,572 lbs
Spread force 2nd plunger 14,612 lbs
Skill saw specs
7 1/4” worm drive saw
4400 rpm
13 amps
120 volts
CO2 extinguish specs
10BC (B=liquid, C=electrical)
3/8” hose
Pressurized to 865 psi
Water can specs
2A rating
2.5 g H2O
3/8” hose
Pressurized to 100psi
Dry Chem extinguisher specs
120BC (B=liquids, C=electrical)
1/2” hose
Pressurized to 195 psi
Met-L-X extinguisher specs
Used for flammable metals
5/8” hose
Cartridge psi 800-900
Tank psi 300-400
Tempest blower (big fan) specs
27”
9 fiberglass fins
24,000 cfm
Tempest blower (small fan)
18” fan
8 blades
16,500 cfm
Ram fan specs
16” diameter fan
21 fan blades
115 Volts
3200 CFM
MPD specs
Pulley rated at 10,000lbs
Descent control rated at 5,100
Becket rated at 7,500
What are 5 things an inspection cut tells you?
Size of members
Direction of members
Type of material used (2x4, metal, wood ect)
Depth of cut (decking)
Smoke and fire conditions
What are the 3 modes of RIC
Standby
Support
Deployment
What is the emergency evacuation signal?
10 seconds of short horn blasts followed by 10 seconds of silence for a total of 50 seconds.
What channels does accountability officer monitor for RIC?
Red 9
Red 14
Red 16
When E-trigger is pushed and a repeater is reached, where does communication go? When repeater is not reached?
Reached= red 16 xlc axs
Not reached= red 14 axs rev
Bubble Cup TFT 1 1/2” nozzle gpm and psi
2 settings 20 GPM and 95 GPM
100 psi
What is 2/3 pump capacity for KME’s and Segrave’s?
KME 1,166
Seagrave 1,000
Address to TC
1845 N Ontario St
Address to station 11
311 E Orange Grove Ave