Training Bullitin 8 Electrical Hazards Flashcards

(33 cards)

1
Q

What is considered high voltage?

A

Over 600 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How big an area should be cleared for a downed conductor?

A

At least 1 pole span

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How often are gauntlet gloves tested by DWP?

A

Every 60 days

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How much do manhole covers weigh?

A

300 pounds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many volts are in street lights?

A

Up to 4800 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

According to training bulletin 8 - electrical hazards, what is extremely high voltage, high voltage and low voltage?

A

Excess of 60k

600-59,999

Under 600

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Street lights can be fed from conductors carrying what voltage?

A

120-6150 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When applying water to an electrical fire, what is the rule for psi, cone and distance from object

A

30/33/100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When using fire line tape to secure an area of life hazards zone, how should you apply strands?

A

Minimum of 3 horizontal lines with fire line or flagging tape at least 1-3 inches in diameter , with the words do not enter or don not cross

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When having occupants remove their own vehicle from possible electrical charge, what is the minimum distance they should move their vehicle from the danger?

A

35 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

DWP can de-energize power lines in a relatively short period of time according to training bulletin 8 a electrical hazards. What is the time frame?

A

Between 5-10 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When operating at a brush fire maintain a safe distance of ____feet from transmission towers, maintain at least ______feet from the outer most wires from transmission lines and never direct a hose stream into heavy plumes of smoke with in _____feet of high voltage wires.

A

35 feet
100 feet
100 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

According to training bulletin 8- electrical hazards, man hole cover can weigh _____lbs, and have been blown ____feet into the air and travelled _____feet

A

300 lbs
75 feet
125 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the flash point of the cooling oil that is used electrical vaults?

A

300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Low voltage secondary lines carry how many volts?

A

120-240 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are AMPS?

A

Current flow

Similar to gpm

AMPS= watts/volts

17
Q

What are volts?

18
Q

What are watts?

A

The amount of actual power

19
Q

Generation facilities generate how much power?

A

4,000-20,000 volts

20
Q

The insulators on transmission towers are how far apart?

A

3’-20’ depending on voltage

21
Q

Receiving stations reduce power to how many volts?

22
Q

Distribution stations reduce power to how many volts?

23
Q

Overhead transformers reduce power to how many volts?

A

120/240 volts

24
Q

What are the 3 ways to determine high voltage lines?

A

1) high voltage signs
2) size of insulators
3) distance between conductors

25
Heart paralysis can occur at how many AMPS?
4
26
Tissue is burned at how many amps?
Greater than 5 amps
27
Respiratory arrest has occurred when shocked at as low as how many volts?
49
28
Communication cables can have up to how many volts?
50
29
What is the explosive range of carbon monoxide?
12.4-74%
30
Wet skin may have a resistance of up to how many ohms? Dry skin?
Wet skin- 1000 ohms Dry skin- 100,000 ohms
31
What is the lowest amps a fuse or circuit breaker will open?
15 AMPS
32
For every minute defibrillation is delayed chance of survival decreases what percent?
10%
33
600 volts can be up to how many amps?
4