Transient Conduction Flashcards
1
Q
When can lumped capacity method be used?
A
When Bi < 0,1
2
Q
How do you find the convection coefficient of a small sphere in an airstream given the temperature time history?
A
- Assume Bi < 0.1
- Use Transient Temperature formula to find b.
- Use b to find h
- Validate assumption 1 using h
3
Q
How do you solve transient electric wire heater in fluid system?
A
- Use Energy Balance: q_el - q_convec = rho V c dT/dt
- Integrate the equation: You will have to use substitutions until you are able to use separation of variables
4
Q
Given a transient sphere system in a stream, how do you use One-term approximation to solve the system?
A
- Calculate Biot Number
- Assume F_0 > 0,2
- Use one-term approximation formula for sphere
- Get the constants for the formula from the table
- Verify assumption 2
5
Q
In what case can one term approximation be used?
A
Fo > 0,2
6
Q
Given a transient sphere system in a stream, how do you use Heisler Charts to solve the system?
A
- Find Bi^-1
- Find theta^*
- Find Fourier number from chart
- Use Graph to find required values