Fill in the blank:
The vertical distance from the fixture outlet to the trap weir shall not exceed ______ inches.
24 inches
Fill in the blank:
A combination plumbing fixture is permitted to be installed on one trap provided that one compartment is not more than ______ inches deeper than the other compartment.
6
Where is a slip joint connection of a trap not permitted?
trap offset
Fill in the blank:
Each fixture trap shall have a trap seal not more than ______ inches deep.
4
True or False:
A trap shall be larger than the drainage pipe into which the trap discharges.
False
True or False:
Acid resistant traps shall be embedded in concrete.
True
Which location does not require a grease interceptor or automatic grease removal device?
residential kitchen
What is the grease retention capacity for an interceptor with a flow-through rate of 10 GPM?
20 pounds
Fill in the blank:
______ shall be provided for inspection and maintenance of automatic grease removal devices.
Ready access
Fill in the blank:
A wire basket on the discharge side of a clothes washer shall prevent the passage of solids ______ inch(es) or larger from being discharged into the public sewer.
1/2
True or False:
The plumbing vent system may be used for purposes other than venting of the plumbing when approved by the code official.
False
Fill in the blank:
Where a rooftop is used for restaurant dining, open vent pipes shall terminate not less than ______ feet above the roof.
7
Fill in the blank:
Any increase in size for vent terminations shall be created not less than ______ inside the thermal envelope.
12 inches
Fill in the blank:
A vent stack is required when there are more than ______ branch intervals in a building.
five
Fill in the blank:
If a vent extends more than ______ feet in developed length, then the vent shall be increased by one nominal pipe size for the entire length.
40
What is the vent pipe size for a drainage system serving a 4” stack carrying 300 DFU with a developed length of 75 feet?
3 inches
True or False:
The developed length may be measured from the farthest point of vent connection to the drainage system to the vent termination outside the building.
True
Fill in the blank:
Relief vents shall be provided for stacks having ______ or more branch intervals
10
What is the maximum distance for a trap arm for a 1 1/4” trap with 1/4” per foot grade?
5 feet
What is the maximum distance for a trap arm for a 3” trap with 1/8” per foot grade?
12 feet
True or False:
Common vented trap fixtures shall be located on the same floor level.
True
True or False:
Fixtures being vented by a horizontal wet vent must be on the same floor level.
True
True or False:
A waste stack vent system is permitted to have 45-degree offsets within the stack.
False
What is the maximum number of fixtures that can be served by a circuit vent?
8