Unit 2 Quiz Flashcards
Requirements for fire and life safety inspections of tents, canopies, and temporary membrane structures can be found in what code?
D - California Fire Code
A tent requires a permit when it is in excess of how many square feet?
C - 400
Does a tent used exclusively for this use not need a permit?
A - Recreation
Exit doors on a tent or temporary structure, when required, must open in which direction?
A - Direction of travel
Which is the definition of a canopy?
C - A structure or architectural projection of ridged construction over which a covering is attached
All permitted tents in the State of California have to be approved and listed as flame-resistant by what agency?
A - State Fire Marshal
At a minimum, one of what class of fire extinguisher is required for a tent with the area of 650 square feet?
D - 2-A
Fireworks are not allowed to be used within how many feet of a tent?
A - 100 feet
What is the minimum aisle width required by code in an employee serving area?
A - 24 inches
When determining the required total width of means of egress for a tent in inches, what is the factor used for inches per person?
D - 0.2
How close can a tent or membrane structure be placed to a lot line?
C - 20 feet
Which of the following is the number of days a temporary membrane structure can be erected for in a 12-month period on a single premise?
D - 180
At what occupant load can the AHJ require at least one qualified fire safety person for stand-by?
C - 500
How close can a vehicle supporting the operation of a tent be to the tent?
C - 20 feet
The minimum aisle width in public areas of a tent or temporary membrane structure is?
D - 44 inches
When are exit signs required by code to be installed in a tent?
D - OL ≥50
If the occupant load of a tent is 500, what is the total width of the means of egress required by code?
A - 100 inches
Cooking and heating equipment shall not be located within how many feet of exits or combustibles?
B - 10 feet
When cooking equipment is used, the venting system must have a clearance of how many inches from all portions of the tent or membrane?
C - 12 inches
Generators must be isolated from the public and separated from the tent or membrane structure by a minimum of how many feet?
C - 20 feet