What is the minimum recommended distribution temperature of hot water supplied by a storage cylinder?
60°C
Which Building Regulation relates to the hot water delivery systems in dwellings?
Part G
What can be classed as a localised hot water system?
Under-sink single point heater
The safety devices within an unvented hot water cylinder are designed to prevent the water from exceeding which temperature?
95°C
Where should a secondary return be connected within a hot water storage cylinder?
Halfway down
What temperature should the temperature relief valve fitted to an unvented hot water storage vessel be set to discharge at?
90°C
Which type of thermostatic mixing valve (TMV) should be installed within NHS and healthcare properties?
TMV3
What is the expected temperature difference between the flow and return in a modern sealed CH system incorporating a condensing type boiler, if designed correctly?
20°C.
Which pipe within an open vented central heating system allows the system to remain at atmospheric pressure?
Open vent pipe.
Which heating system incorporates 2 x two-port valves?
S plan
Which type of boiler utilises increased efficiency by recovering latent heat from the flue gases?
c Condensing boiler
What is the recommended installation height from the floor for a radiator?
b 150 mm
Within a sealed heating system, which component accommodates the expansion of water during heating?
d Expansion vessel
Which part of the Building Regulations specifically covers rainwater systems?
Document H
What is the recommended clipping distance for PVCu gutters to fascia boards?
750 mm
Which of the following British Standards gives specific information on the intensity of rainfall in the UK?
BS EN 12056-3:2000
Which building regulation must sanitation systems comply with?
a Part G
What is the minimum trap seal depth for a bath?
b 50 mm
What is the maximum length of waste pipe from a bath when connecting to a primary vented stack?
b 3 m
When a stack is installed within 3 m of an openable window, what minimum distance above that window should it terminate?
c 900 mm
What is the maximum vertical distance below a branch connection into a stack (82 mm to 160 mm in diameter) where no other connection is allowed?
200 mm
Which British Standard offers specific guidance on the space requirements for sanitary appliances?
BS 6465-2