What is used to provide supplemental heat for a heat-pump window unit?
Electric resistive heater strips
Single room air conditioning units generally range in capacity from ______ btu/h.
4000 to 24,000
The evaporator typically operates _______ the dew point temperature of the room air.
Below
Compressors used in window air conditioners are typically hermetically sealed and either _____ or _______.
Reciprocating or rotary
True or false: all 208V/230V power cords have the same plug configuration.
False
True or false: In the heat-pump heating cycle, the refrigerant condenses in the indoor coil.
True
True or false: The capacity of a heat-pump is less in colder weather so supplemental heat will probably be provided.
True
True or false: The heat-pump systems use a three-way reversing valve and check valves to ensure correct flow through the correct metering device at the proper time.
False
True or false: The most common refrigerant used in older window air conditioners is R-12
False
True or false: New models of window air conditioners use R-410A refrigerant.
True
Coil temperature for a window air conditioner should be no lower than _______ F.
35 degrees F
How is the condensate from the evaporator disposed of from a window unit?
Drained out of the pan or evaporation using a slinger ring
When doing a bench test to check a window unit to see if it has a proper charge, what is the purpose of blocking the condenser air flow?
Because the condenser and evaporator will be operating in the same ambient temperature, blocking the airflow over the condenser will increase head pressure and push the refrigerant out of the condenser.
The round piece fastened to the outer tips of the condenser fan blade is called the ______.
Slinger ring
The window unit must be installed in such a manner that air can circulate across the _______ and not recirculate or high head pressures will result.
Condenser
What happens if a window air conditioner is installed with an inward pitch?
Condensate could leak into the room
What is the result of a dirty air filter on a window unit?
Dirty coils
low suction pressure
potential ice blockage in the evaporator
Window installation of room units are either double-hung or ______ windows.
Casement
What is the purpose of the energy saver switch on some window units?
To allow or deny the fan motor from cycling on/off with the compressor
When bench checking a window unit for a low charge, where should the sweat line be to indicate a full charge?
All the way to the compressor
The correct head pressure for a window unit that uses R-410A is ______ psig.
420
What is performed on a window unit for basic preventive maintenance?
- Cleaning the filters and coils
- lubricating the motor if needed
- clean out condensate drain pan
- clean blower fan blades
- check for mold on the foam insulation
- check capacitor
How can you identify if a window unit is a through-the-wall type unit?
The sides will not have vents/louvers.
What type of fan motor is used in a window unit?
PSC or Shaded pole