What is required on horizontal hall doors to keep the door panel closed in position if the primary guiding means fail as per ASME A17.1/CSA B44?
Retainers
How should door tracks be installed?
Exactly level & parallel w/ sill
Why are eccentrics required on door hangers as per ASME A17.1/CSA B44?
Prevent hanger sheave from disengaging from track
How must all hall doors interlocks be wired?
In series
How should centre opening doors be hung?
Plumb at centre of opening
Why are sills grouted?
Ensure load bearing capacity
What is the purpose of the header
Support hoistway entrance, door hangers, panels & track
Why would it be advised to run a string across all door frames in a multi-bank hoistway?
Ensure frames are aligned to each other
What must hall door closers ensure?
Hall door is self closing throughout whole travel of door
What is an acceptable means to have the locking member of the interlock hold the door in the locked position as per ASME A17.1/CSA B44?
Gravity, restrained compression spring, positive linkage