One hundred twenty five percent of theoretical air
was supplied for combustion. What is the equivalent
excess air equal to?
25%
The size of a reciprocating pump is stamped on the
builder’s plate as 3 x 4 x 6. The diameter of the
liquid cylinder is:
4 inches
Ice cubes were added to a glass of water and
stirred. Moisture starts to condense at the outer
surface of the glass, what is the temperature of
the moisture at the outer surface?
Dew point temperature
A steam generator produces 1007 Btu per lbm of heat
at 100 psia from 14.7 psia of saturated liquid. If
the heat input supplied is 800 Btu per Ibm, which
of the following is true for the device?
A. The device cannot work because the pressure is
greater than zero.
B. The device can work because output is greater
than input.
C. The device violates the first law of
thermodynamics because output is greater than
input.
D.
The
device violates the second law of
thermodynamics because input is less than output.
C
If cavitation will occur, the available NPSH is
insufficient. Which of the following is a remedy
to overcome cavitation?
increase the available NPSH
A boiler testing method that is used to verify the
microstructure of the boiler tubes using optical
microscopes.
metallurgical replication
It is important to take some moisture from the air
to dehumidify it and the relative humidity reaches
high levels. To do this, it requires cooling the
air
below its dew point temperature.
Freon flows through an expansion valve, select the
best statement:
A. the temperature increases
B. the pressure remains constant
C. the internal energy remains constant
D. the enthalpy remains constant
D
Class of fire involving combustible metals such as magnesium, sodium, titanium and other similar metals.
Class D
Cooling air in intercoolers between compression
stages in a multi-stage air compressor.
keeps the moisture in the air from evaporating
For comfort cooling, the amount of air recirculated and only enough outside air is introduced to provide for ventilation requirements, approximately from _______ cu ft per minute per
occupant.
10 to 15 cu. ft per minute per occupant.
Suitable means shall be provided for the collection
and disposal of condensate from the equipment. The
condensate drain shall be at least _____ nominal
pipe size and shall be copper, galvanized steel,
or other corrosion-resistant material
19 mm
Fire code of the Philippines:
PD No. 1185
National Building Code of the Philippines
RA 6541
Occupational, Safety, and Health
RA 11058
Clean water act of the Philippines
RA 9275
Flow test and Hydrants Standards
NFPA 291
In industrial plant practice, what is the type of
conveyor commonly used for conveying bulk materials
over long distances because they are least
expensive and most versatile?
Belt Conveyor
What is an automatic pressure-relieving device
actuated by the static pressure upstream of such
device, characterized by the full opening pop
action? It is mainly used for gas or vapor service.
Safety Valve
Per Section 1302 Mechanical Regulations of the
National Building Code of the Philippines PD1096
2005, BOILERS may be located inside buildings but
the minimum distance from any wall shall be at
least _______ meters.
1.5 m
What type of sprinkler system employs open
sprinklers attached to a piping system connected
to a water supply through a valve that is opened
by the operation of a detection system in the same
area as the sprinkler system. When activated, water
flows and discharges to all sprinklers at the same
time.
Deluge system
The Philippine Clean Air Act of 1999 (RA 8749)
specifies the limit of Sox (as SO2) that can be
discharge to the environment, in mg/Nm3, as ______.
<700
You are supervising the installation of a steam
driven reciprocating pump. The pump’s air chamber
is missing and you have to replace it with one with
several salvaged ones. The salvaged air chamber
selected should have a volume equal to, most
nearly,:
A. Half of the position displacement of the pump
B. 1 ½ times the position displacement of the pump
C. 2 times the piston displacement of the pump
D. 2 ½ times the piston displacement of the pump
D
In accordance with the air pollution control code,
no person shall cause or permit the emission of air
contaminants from a boiler with a capacity of 500
million BTU sulfur dioxide content of more than:
200 ppm (parts per million), 10% excess air