What is mechanical index?

A

Relative potential for ultrasound to induce an adverse biotech by a nonthermal mechanism (cavitation)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is thermal index?

A

Indicator of the relative potential for a tissue temperature rise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What threshold should the MI and TI be kept under?

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are some ways of keeping the MI and TI under threshold?

A
  • Begin at a low power output and increase power only if necessary
  • Incorporate ALARA
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the safety considerations with Doppler ultrasound during first trimester scans?

A
  • Pulsed Doppler (spectral, power and colour) should not be used routinely
  • Pulsed Doppler may be used for clinical indications to refine risks for trisomies
  • The thermal index should be less than, or equal to 1 and exposure time should be kept as short as possible (usually no longer than 5-10mins) and not exceed 60 mins.
  • Can implement ALARA which means ‘as low as reasonably achievable’
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the purpose of first, second and third trimester scans?

A

First is to ensure fetal viability, dating, localisation and number of fetus’, second is for fetal anatomy scanning and third is fetal well-being.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the three important parameters under end-user control?

A
  • Dwell time
  • System setup and output control
  • Scanning/operation mode
  • Transducer choice
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

ASUM policy states that diagnostic exposure to ultrasound should not produce what?

A

1.5°C increase in temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Why is choice of scanning mode important?

A

Different modes offer varying levels of detail, image quality, and energy exposure, which can impact the accuracy and safety of the scan.

Spatial peak temporal average intensity (ISPTA) increases from B-mode (34 mW/cm2) to over 1180 mW/cm2 in Doppler and spectral Doppler

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Why does colour Doppler have higher intensities than b-mode?

A

Because it needs to detect and process more information about blood flow which involves analyzing subtle changes in frequency due to the Doppler effect. Due to of mode of operation: sequences of pulses, scanned through the area of interest (“box”).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Why is transducer choice important in regards to ultrasound safety?

A

Transducer choice is important because it will determine frequency, penetration, resolution, and field of view

How well did you know this?
1
Not at all
2
3
4
5
Perfectly