Wiring Rules Flashcards

1
Q

Wiring systems must not have excessive _____ ____.

A

Voltage Drop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

All wring materials must be _____.

A

Listed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Overhead conductors must be kept at least ____ ft away from water wells.

A

20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Aluminum conductors smaller than ____ may not be used.

A

6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

_____ construction must be energy efficient.

A

New

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Submerged electrical equipment _____ to be replaced

A

Needs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Smoke alarms must be installed in every _____ area

A

Sleeping

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Submerged electrical wiring _____ need to be replaced

A

Might

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Each ____ of a dwelling unit must have a smoke detector.

A

Story

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A smoke detector must be installed in a living room at the end of a hallway if the ceiling in the living room is more than ____ higher than the hallway ceiling

A

24”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

______ alarms must be installed in attached garages.

A

Heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Carbon monoxide alarms must be installed outside each _____ area in a dwelling.

A

Sleeping

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Smoke alarms must get their power from the ______ wiring.

A

Building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Smoke alarms must have ____ backup

A

Battery

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

_____ alarms must be interconnected with the smoke alarms.

A

Heat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Apartments must have an _______ and _____ fire alarm system

A

Automatic / Manual

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Electrical equipment associated with the heating system must be on a _____ circuit.

A

Separate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Kitchens in public gathering places like schools and churches must have ___ 20 amp small appliance circuits

A

6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Dwelling units must have ____ 20 amp small appliance circuits.

17
Q

Adjacent receptacle outlets above the kitchen countertops may not be on the ______ ______.

A

Same Circuit

18
Q

A 20 amp bathroom receptacle outlet circuit may not supply more than ____ bathrooms?

19
Q

Receptacles for sewer pumps and sump pumps do not require ____ protection.

20
Q

GFCI protection is not required for a single receptacle for a sump pump as long as it is on a _____ circuit

21
Q

No point along a corridor may be more than ____ ft from a receptacle outlet for portable cleaning equipment.

22
GFCI protection for the garage door opener receptacle is not required if you use a ____ receptacle.
Single
23
AFCI protection is not required for a single receptacle supplying a refrigerator if its on a ______ circuit.
Dedicated
24
A service must be ___ inch RMC or IMC?
2
25
Outdoor service switches may be mounted no lower than __ ft above grade within __ ft of structure
2 / 10
26
The smallest service allowed for a single family dwelling is ___ amps
100
27
A 100 amp house panel requires ___ spaces, a panel over 100 amps but less than 200 amps requires ___ spaces and a 200 amp panel requires ___ spaces
20 / 30 / 40
28
Service and feeder calculations for electric heat must be sized to ____%.
125%
29
Outdoor overcurrent devices may not be mounted lower than ___ ft above grade.
2
30
Switchboards and panelboards shall not be located where?
Bathrooms, clothing closets, stairways, or crawl spaces.
31
A lighting standard is at least ___ ft high
12
32
A #____ copper bonding jumper must be used to bond the lighting standard to the equipment grounding conductor and the ___ ft ground rod or ___ ft of 1/2" rebar.
8 / 10 / 20
33
The grounding electrode conductor must be connected to the grounded service conductor in the enclosure for the ______ _______.
Service Disconnect
34
EMT may not be used in a concrete slab that is in contact with the _____.
Earth
35
Aluminum conduit may not be used in the earth or embedded in _______.
Concrete
36
The range of outdoor temps in ND is considered to be ______ degrees F.
140
37
Wiring must be brought up to the 2017 NEC standards where the wall covering has been removed from ____ walls.
All
38
Metal raceways or _____ must be used when wiring a place of assembly
MC Cable
39
Fire alarm cable must be placed in metal raceways when wiring a place of assembly unless the cable has a ___ hour fire rating.
2
40
Not more than ___ extension ring may be used on a box
One
41
Up to a ___ ft cord may be used for powering a fuel fired furnace in a dwelling unit
6
42
Surge arrestors must be provided for all services in ___ ______.
Grain Elevators
43
For externally illuminated exit signs the letters must be at least ____ " high.
6"
44
The minimum lighting level for egress must be ___ ft-candle at floor level
1 ft