According to Book 57 (The 2020 Los Angeles Fire Code - Chapter 10
Section 1004.6) The occupant load of seating booths shall be based on
one person for each _ inches of booth seat length measured at the
backrest of the seating booth.
24”
According to Book 57 (The 2020 Los Angeles Fire Code - Chapter 10
Section 1005.7.1) Doors. Door when fully opened shall not reduce the
required width by more than _ inches
7”
According to Book 57 (The 2020 Los Angeles Fire Code - Chapter 10
Section Table 1006.2.1) Maximum Common Path of Egress Travel
Distance in a Educational (Group E) Occupancy is_ feet
75ft
According to Book 57 (The 2020 Los Angeles Fire Code- Chapter 10
Section 1006.2.1.1) Three or more exist access doorways. An occupant
load of 500 requires how many exit access doorways?
2
- According to Book 57 (The 2020 Los Angeles Fire Code - Chapter 10
Section 1008.2.1) llumination under normal power. The means of egress
illumination level shall be not less than___ footcandle(s) at the walking
surface.
1 footcandle
According to Book 57 (The 2020 Los Angeles Fire Code- Chapter 10
Section 1008.3.4) Duration> The emergency power system shall provide
power for a duration not less than_ minutes and shall consist of
storage batteries, unit equipment or an on site generator.
90 minutes
According to Book 57 (The 2020 Los Angeles Fire Code - Chapter 10
Section 1008.3.3 ) Rooms and Spaces. In the event of power supply
failure, an emergency electrical system shall automatically illuminate all
of the following areas: Electrical Rooms, Fire Command Centers, Fire
Pump Rooms, Generator Rooms and Public Restrooms with an area
greater than_ square feet?
300 sq ft
According to Book 57 (The 2020 Los Angeles Fire Code - Chapter 10
Section 1009.3.2) Stairway Width for accessible egress. Stairways shall
have a clear width of _ inches minimum between handrails.
48”
According to Book 57 (The 2020 Los Angeles Fire Code - Chapter 10
Section 1011.3 Headroom) Stairways shall have a minimum clearance of
not less than _ inches measured vertically from a line connecting the
edge of nosing.
80”
According to Book 57 (The 2020 Los Angeles Fire Code - Chapter 10
Section 1010.1.10.1) Where panic or fire exit hardware is installed, the
maximum unlatching force shall not exceed _ pounds
15lbs
According to the Los Angeles Fire Department Library Book 1 Basic
Inspection Guide, Section 57.33.17) Stairway Identification Signs shall be
square with a minimum dimension of __ inches
12”
According to the Los Angeles Fire Department Library Book 1 Basic
Inspection Guide, Section 57.22.04) Permit. A special permit is required
for storage, display, sale, or other use of Christmas Trees within buildings
where more than_ trees are located.
10
According to the Los Angeles Fire Department Library Book 1 Basic
Inspection Guide, Section 57.80.09) Spray Booths, A permit is required to
erect, install or relocate spray booths or spray tunnel with any dimension
greater than_ feet
3ft
According to the Los Angeles Fire Department Library Book 1 Basic
Inspection Guide, (Section 57.138.13 Fire Department Connection Signs )
Fire Hose Cabinets that contain a fire extinguisher shall also be identified
with a sign stating “‘Fire Extinguisher* with letter no less than__ inches
on contrasting background.
3 “
According to the Los Angeles Fire Department Library Book 1 Basic
Inspection Guide, (Section 57.30.05) Table 30-B Permits: A Permit is
required for Class IA Flammable liquid in quantities greater than
Gallons
60 gallons
According to the Los Angeles Fire Department Library, Training
Bulletin 42 Single Station Smoke Detectors: Six out of ten fatal home fires
start between the hours of_&?
9pm & 6am
According to the Los Angeles Fire Department Library, Training
Bulletin 42 Single Station Smoke Detectors: Detectors are approved to
give an area coverage equivalent to a_ foot diameter.
25 ft
According to the Los Angeles Fire Department Library, Training
Bulletin 42 Single Station Smoke Detectors: A Smoke Detector can be
moved __ feet from a bedroom door and still provide coverage.
12.5 ft
According to the Los Angeles Fire Department Library, Training
Bulletin 42 Single Station Smoke Detectors: Only Smoke Detectors
Approve by
can be sold or installed in California
California State Fire Marshal’s Office
According to the Los Angeles Fire Department Library, Training
Bulletin 42 Single Station Smoke Detectors: All Detectors must meet the
following listing to be approved for use in California?
UL 217
According to the Los Angeles Fire Department Library, Departmental
Bulletin 11-14 (Automatic Alarm Reduction Program) According the
DB11-14 the Los Angeles Fire Department responds to over
Automatic Alarms per month.
1000
According to the Los Angeles Fire Department Library, Departmental
Bulletin 11-14 (Automatic Alarm Reduction Program) According to DB 11
-14 Automatic Alarm Data will be collected on a
basis and a
report of the worst offenders will be provided to the FPB.
Monthly
According to the Los Angeles Fire Department Library. Departmental
Bulletin 11-14 (Automatic Alarm Reduction Program) The duration of the
Autoratic Alarm Reduction Program was
6 months
According to the Los Angeles Fire Department Library, Departmental
Bulletin 11-14 (Automatic Alarm Reduction Program) When the fire
department arrives to an Intrusion alarm with no additional activations
the responding Officer is required to provide
with specified
information via email
On Duty OCD Battalion Commander