Anounciator Pannel Flashcards

1
Q

Red FUEL PX

A

Indicates less than 10 PSI of fuel pressure in the motive flow/return flow supply line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Green BOOST PUMP

A

Boost pump on when:
Boost pump switch on
Start is activates regardless of px

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Amber L FUEL LO/ R FUEL LO

A

Optical sensor activated when fuel quantity is below 110 lbs in the respective tank.

Independent from fuel flow and quantity sensors.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Amber FUEL BAL

A

Fuel imbalance exceeds 30 lbs for 2 mins
OR
A fuel prob fails

Reset the auto balancer by cycling FUEL BAL switch and this restarts 2 min timer.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Green M FUEL BAL

A

When FUEL BAL switch is in manual mode

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Amber FP FUEL on AEDD

A

Fuel prob failure: do not attempt manual balance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Amber HYDR FL LO

A

Reservoir level has dropped below ~ 1 quart

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Amber EHYD PX LO

A

When emergency pressure drops below 2400+/-150 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Red OBOGS FAIL

A

Either
Low bleed air pressure upstream of concentrator
Or
Internal failure detected by OBOGS BIT on start or by initiating test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Red OIL PX

A

When oil pressure drops below
- 40 psi above idle
- 15 psi at idle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly