201.04 PZR, PRT, and RCDT Flashcards

1
Q
  • 201.04 PZR, PRT, and RCDT*
    • *

Pressurizer Functions

A

Attain normal operating pressure of 2235 psig during plant heatup

Maintain required pressure during steady state operations

Limit pressure changes caused by coolant thermal expansion and contraction

Assure no bulk boiling during Condition I or II accidents

Prevent primary pressure from exceeding 110% of design (2500 psia) at 2735 psig (T.S. Safety Limit)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • 201.04 PZR, PRT, and RCDT*
    • *

PZR Heater Function

A

puts energy into PZR water volume to raise temperature and pressure

  • 117 heaters*
  • 17.95 KW each*
  • 2100 KW total*
  • Nichrome wire w/ magnesium oxide insulator*
  • Hermetically sealed, designed for full pressure in event of sheath leak*
  • (2485 psig at 680 F)*
How well did you know this?
1
Not at all
2
3
4
5
Perfectly