201.02 RCS Flashcards

1
Q
  • 201.02 RCS*
    • *

Functions of RCS

A

Transport heat from Rx to S/G.

Act as a moderator and a reflector.

Solvent for neutron absorber.

Second boundary of protection against release of fission product to the public.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • 201.02 RCS*
    • *

Describe flowpaths through RCS

A

Through core - out through hot leg to steam generator. Through S/G U-TUBES through the crossover leg to the suction of the RCP. The pump discharges back into the reactor vessel and core.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

RCS piping sizes

A

Hot Leg 29” ID

Cold Leg 27.5” ID

Intermediate Leg 31” ID

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

RCS Design Data

Flow Rate -

Total Volume -

Operating Liquid Vol. -

Loop Transit Time -

Rated Thermal Power (RTP) -

Tave -

Design Press -

Life -

A

Flow Rate - 107,800 gpm per pump

Total Volume - 14,974 ft3

Operating Liquid Vol. - 13,352 ft3

Loop Transit Time - 13.2 sec

Rated Thermal Power (RTP) - 3853 MWt

Tave - 567oF - 593oF

Design Press - 2485 psig

Life - 40 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • 201.02 RCS*
    • *

Function of Interfacing Systems:

Pressurizer

A

Attainment of operating pressure.

Maintain required pressure.

Limit RCS pressure changes during load changes to allowable limits.

Prevent RCS overpressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  • 201.02 RCS*
    • *

Function of Interfacing Systems:

CVCS

A

Purify Reactor Coolant

Provide a Means of Chemistry Control

Provide a Means of Varying CB

Maintain RCS Inventory

Supply RCP Seal Water

Provide a Means for Filling, Draining, and Pressure Testing of the RCS.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  • 201.02 RCS*
    • *

Function of Interfacing Systems:

RHR System

A

Decay Heat Removal.

Solid Plant Pressure Control in Conjunction with CVCS.

RHR Heat Exchanger used in ECCS.

Transfer Refueling Water from Refueling Cavity to the RWST.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
  • 201.02 RCS*
    • *

Function of Interfacing Systems:

Safety Injection

A

Provides Borated Water for Emergency Core Cooling in the Event of a LOCA or Steam Break Accident.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  • 201.02 RCS*
    • *

Function of Interfacing Systems:

Sampling

A

Provides access to RCS fluids to obtain chemistry samples.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
  • 201.02 RCS*
    • *

Function of Interfacing Systems:

Drains

A

Drains to RCDT are located on each loop crossover leg low point

2” lines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
  • 201.02 RCS*
    • *

Instrumentation and Controls to monitor / operate:

Loop Avg Temp Fast Response RTDs

A

HL

(3) T-hots per loop, located on hot leg before SGs.

CL

(1) T-cold per loop, located downstream RCPs.

Used to generate “Tavg” and Delta T

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
  • 201.02 RCS*
    • *

Instrumentation and Controls to monitor / operate:

Pressurizer Safety and Relief Valve Discharge Temperatures

A

PORVs (TI-676), Safeties (TI-677, 678, 679)

RTDs installed in each tailpipe

Generates high alarm (150°F), indicating valve leakage or valve open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
  • 201.02 RCS*
    • *

Instrumentation and Controls to monitor / operate:

Pressurizer Liquid and Vapor Space Temperature

A

Liquid (TI-608), Vapor (TI-607)

(2) RTDs one in liquid, one in vapor

Indicates saturation in PRZR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly