API 570 data sheets - Dimesions Flashcards
NDE - Maximum Length of crack or incomplete fusion allowed on a new weld
0”
B31.3 Tbl 341.3.2
Design -Mill Tolerance For rolled and welded pipe
- 0.010”
574: 4.1.13
Flanges - Typical flange face finish
125 - 250 micro inch
B16.5: 6.4.5.3
Flanges - When mating flanges, the maximum amount of un parallel allowed (per diameter of flange in feet)
1/16” per foot
B31.3: 335.1.c.1
Flanges - Max offset four bolt-holes for mating flanges
1/8”
B31.1: 335.1.c.3
Welding - Maximum allowed size of open discontinuity in a bend test
1/8”
Sect IX: QW-163
Preheat Zone - Distance from toe of weld
1”
B31.3: 330.1.4
PWHT Zone - Distance from toe of weld
1”
B31.3: 331.2.6
NDE- Minimum distance beyond the area to be examined to clean a part when performing a MT examination
1”
Sect V: T-741.1.b
NDE- Minimum distance beyond the area to be examined to clean a part when performing a PT examination
1”
Sect V: T-642.b
Repairs - Minimum radius of insert patch
1”
570: 8.1.4.2.c
NDE- Max diameter of CML exam point for lines less than 10 NPS
2”
570: 3.1.20
NDE- Max diameter of CML exam point for lines greater than 10 NPS
3”
570: 3.1.20
NDE- Minimum length of spot RT
6”
B31.3: 344.5.2.c
Welding - Minimum length to RT/UT when qualifying a welder with test coupon or 1st production weld
6”
IX: QW- 302.2/ 304.1