API 570 data sheets - key words/ Services Flashcards

0
Q

Define - repair

A

Restore- suitable

570: 3.78

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

Define - alteration

A

Physical change

570: 3.1.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Define - Imperfection that exceeds an acceptable criteria

A

Defect

570: 3.1.17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Define - Discontinuity that may or may not exceed the acceptance criteria

A

Imperfection

570: 3.1.30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Define - RBI’s Two primary factors

A

Probability and consequence

570: 5.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

NDE - Number of CML’s to obtain thickness readings during inspections

A

Representative

570: 6.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

NDE - CML that must be measured during a thickness Inspection

A

CML w/ earliest renewal date

570: 6.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

PRD’S - How relief device intervals are determined

A

Performance

570: 6.7.3.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Inspection - Basis of API 570’s Piping Classification

A

Consequence of Failure

570: 6.3.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Corrosion - Method by which process leaks can be lead to brittle failure

A

Auto-refrigeration

570: 6.3.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Corrosion - Cause for fatigue crack

A

Cyclic Stress

574: 7.4.10.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Corrosion - Factors that affect the creep rate

A

TIME, TEMPERATURE & STRESS

574: 7.4.11.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

CORROSION - Type of soil that is most corrosive

A

Low Resistivity

570: 9.2.4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Repairs - # of new flange assemblies to be inspected during repairs and alterations

A

Representative

570: 5.12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

SCC can develop at hot spots, including where the heat tracing attaches to pipe

A

Caustic

574: 7.4.6.2.n

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where dew point corrosion often occurs

A

Overhead - Fractionation

574: 7.4.6.2.b

16
Q

Potential for none or very few CML’s on circuit

A

Olefin cold side, Anhydrous ammonia

570: 5.6.2

17
Q

Relatively uniform corrosion

A

Sulfidation, sour water

570: 5.6.3

18
Q

Valves that should be expected for thermal fatigue

A

Cat Reformer

570: 5.10