API 570- data sheets Miscellaneous other (26) Flashcards
NDE - weight you to check my magnetic strength of DC yoke
40 lbs
V: T-762.c
NDE - Weight used to check magnetic strength of an AC yoke
10 lbs
V: T-762.b
NDE - Weight used to check magnetic strength of a permanent magnet yoke
40 lbs
V: T-762.c
NDE - min angle of eye-to-part to count as a visual exam
30 degress
V: T-952
NDE- Two primary gamma-ray RT sources
Ir-192 & Co 60
577: 9.8.4
NDE - Lead letter used during RT to check for backscatter radiation
B
V: T-223
NDE - lead letter used during RT to indicate a film-side IQI
F
V: T-277.1.b
NDE- Hole size that must be visible in RT when using a hole-type IQI
2T
V: tbl T-276
NDE- minimum light intensity when performing MT or PT fluorescent exams
100 ft-canles
V: T-676.3, T-777.1, T-952
NDE - Minimum black light intensity when performing MT or PT fluorescent exams
1000 mW/cm2
NDE - Maximum UT scanning speed
6”/ sec
574: 10.2.1.4.3
Weld qualification- Maximum allowed thickness on a WPS based on the plate thickness (T) of a PQR test coupon
2T
IX: QW-451.1
Weld qualification - The “all-position” test coupon
6G
IX: QW-461.9
Weld Qualification - Rejectable in RT when qualifying a welder
crack.LOF, IP
IX: QW-191.1.2.2.a.1
Weld Qualification - which welding process can a welder NOT be qualified by RT/UT
GMAW-SC (sc- short circuit)
IX: QW-304