Apparatus P-3 Basic Pumping Operations Flashcards

1
Q

Transfer valve enables pump to operate in VOLUME or pressure.

A

SOP is VOLUME POSITION

exception: overcome head pressures/STANDPIPE OPS…change before lines are charged

do not confuse with PPG’s PRESSURE MODE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

PUMP IDLE PRESSURE?

A

apparatus is at its LOWEST RPMS
this equals pressure PUMPS PROVIDE (55 in volume/110 in pressure ) PLUS water intake pressure received from hydrant (50 psi or so)

50+55= 105 pump idle pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

PPG?

A

computer that controls discharge pressure by controlling engine RPMs

PPG can operate in PRESSURE (standard) or RPM(this mode , WILL NOT automatically compensate for any changes in discharge pressure…this is only EMERGENCY BACK UP, if pressure mode malfunctions )

FOR THIS REASON, ALWAYS OPERATE IN PRESSURE MODE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Static Pressure?

A

INTAKE pressure gauge , water is NOT FLOWING (pressure from hydrant)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

RESIDUAL PRESSURE?

A

remaining pressure indicated on INTAKE gauge once WATER IS FLOWING (stair is 60 psi, water flowing , intake pressure will drop, this is RESIDUAL )

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

FLOWMETER:

A

only when water is FLOWING…Gallons per minute

Flowmeters can be used for ECC to determine problems

Example: ECC supplies correct pressure to 1 3/4” line operating at fire and correct flow meter reading is approx. 180 GPM….suddenly , officer is calling for more water and the ECC notes that flowmeter has dropped to 110 GPM…indication of KINKS….

Same situation….officer reports LOSS OF PRESSURE, but flowmeter reading has INCREASED TO 230 GPM…indicates BURST LENGTH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

HYDRANTS that will be used shall be TESTED BEFORE HOOKING UP.

A

Flush hydrant: do NOT open fully, open several turns and let water push out debris gently…then open FULLY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

HYDRANT CONNECTIONS:

A

FIRST TO ARRIVE- 10’ small/35’ soft suction

Other than first to arrive on FIRST ALARM- 10’small/10’hard/35’ soft suction

arriving on 2nd alarm or greater- 10’ hard

DRAFTING- 10’ HARD

blocked out- length of 3 1/2” hose or 35’ soft–if it can reach

IN line pumping - 3 1/2” hose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Connect to hydrant ______, in case repositioning is required.

A

FIRST, before hooking up to apparatus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Charging pump (insure all drains, discharges and inlets are in closed position)..

A

Open HYDRANT FULLY (don’t confuse with flushing hydrant)

open GATED INLET FULLY (open drain to expel air prior to opening gate)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

It is important to NOTE hydrant intake pressure at the outset of an operation.

A

when RESIDUAL PRESSURE DROPS BELOW 15 PSI on INTAKE pressure gauge, AUGMENTATION is required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Pump must PRIMED(AFTER WATER is introduced, before increasing pump pressure), before?

A

opening INITIAL LINE AT ANY OPERATION

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When PPG is malfunctioning , the apparatus shall be placed ?

A

OUT OF SERVICE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Increase and Decrease on PPG, will allow pressure from 45 PSI to 600 PSI..

A

pressure will ramp up at 1 psi increments when pressed momentarily…it will ramp up and down at 5 psi and then 10 psi when held down for more than 1 second

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Preset is based on what?

A

typical hydrant pressures in ENGINE COMPANY’S response area combined with pressure the pump typically idles at IN VOLUME (55 +50=105 preset–idle pressure)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

A setting in the LED display of the PPG, which is LOWER than the pump idle pressure, will result in the PPG being ?

A

INACTIVE TO THAT POINT

17
Q

Handline Pressures ?

A

1 3/4” hose with 15/16” nozzle=50 PSI @ nozzle+20 psi per friction loss

2 1/2” hose with 1 1/8” nozzle =40 psi @ nozzle+5 psi per length friction loss

5 PSI for EACH FLOOR ABOVE GRADE

-size+number of lengths of hose+nozzle pressure and elevation

18
Q

Notify____when your on BOOSTER TANK WATER…when augmenting with hydrant, you must bring water through_______…, then notify _____when your on ______?

A

OFFICER

GATED INLET

OFFICER

HYDRANT WATER

19
Q

If intake drops below 15 PSI, notify ?

A

INCIDENT COMMANDER

20
Q

Use HOSE TAGES, GREASE PENCIL or chalk when marking discharge..

A

closing wrong discharge is a serious matter

open and close discharge gates SLOWLY

21
Q

When drafting water , use ____position?

A

VOLUME

22
Q

In all cases, run engine at lowest speed at which required pressure can be maintained..

A

to prevent possible damage to pumps (over heating ) keep water flowing through a drain on one of discharge gates and/or operate by pass cooler