AS3000 Flashcards

Electrica wiring standard (31 cards)

1
Q

1.4.2 Accessible is not more than what height above the normal standing surface?

A

2m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

1.4.12 Arms reach is what measurement?

A

2.5m up 1.25m out 0.75m below back

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

1.14 Authorised person

A

Person in charge of premises
licensed electrical contractor
person appointed by person in charge to perform certain duties

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

1.4.15 Available readily

A

can be reached without dismantling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

1.4.16 Barrier

A

provides basic protection from usual direct access

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

1.4.21 cable MIMS

A

mineral insulated metal sheathed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

describe MIMS

A

compressed metal powder mineral insulation enclosed in solid drawn metal sheathing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

1.4.22 cable neutral screened

A

cores surrounded by concentric wire outer conductor further protected by an insulated sheath

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

1.4.24 ceiling, suspended

A

hung from floor or roof above AS/NZ2785

not nailed timber AS/NZ2589.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

1.4.27 Class I equipment

A

does not rely on basic insulation only

accessable conductive parts connected to earthing conductor so as not to be live in basic insulation failure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Class I may have..

A

double insulation

parts operating at SELV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

1.4.28 Class II equipment

A

does not rely on basic insulation only
double or reinforced insulation etc
no provision for protective earthing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Class II types

A

insulation encased
metal encased
combination of above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

insulation encased class II

A

durable, substantially continuous insulating enclosure of all metal parts except small parts isolated from live parts by at least reinforced insulation.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

metal encased class II

A

substantiallly continuous metal enclosure, double insulation used throughout except where impracticable then reinforced insulation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

1.4.29 Class III Equipment

A

SELV Supply, no voltage generated above SELV

17
Q

1.4.33 Consumer mains

A

conductors between POA and main switchboard

18
Q

1.4.34 contact indirect

A

contact with part live under fault conditions

19
Q

1.4.36 current fault

A

insulation failure or bridging

20
Q

1.4.38 current overload

A

overcurrent in as n electrically sound circuit

21
Q

1.4.39 current short circuit

A

fault of negligible impedence between live conductors of differing voltage

22
Q

short circuit current other names

A

prospective short ciruit current

bolted fault

23
Q

short circuit current value

A

maximum fault current

three phase rms unless stated otherwise

24
Q

1.4.44 Earthed situation

A

within 2.5m of a conductive standing service
external to a building
within 2.5m of floor in rooms containing socket outlets and simultaneous contact is possible
all parts of wet area rooms

25
1.4.53 Exposed conductive part
can be touched with standard finger test AS 3100 | can become live if badic insulation fails
26
1.4.54 Extraneous conductive part
not part of installation but may be equipotential to earth.
27
Basic insulation
provides badic protection | not always used soley for functional purposes
28
Supplementary insulation
Independent of basic insulation. | ensures protection if basic insulation fails
29
Double insulation
Combines both badic and supplementary insulation.
30
Double insulation cables
sheathed to AS5000 sheathed flexible to AS3191 not inc 'light duty' sheathed neutral screened to AS4961
31
Reinforced insulation
insulation system equivalent to double insulation under conditions add pecified in AS3100 Aerial bundled cable to AS3560