Building Components (IDPX/PRAC) Flashcards

1
Q

Soiled core doors have a fire rating of what?

A

20, 45 or 90 minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Hollow core doors have fire rating of what?

A

None

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Door components diagram

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Wood door frames have a fire rating of what?

A

20, 30 or 45 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Metal door frames have a fire rating of what?

A

1-hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What type of door frame is used in commerical construction?

A

Steel (door and frame)

Hollow metal door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Alumunium frames have a fire rating of what?

A

20 min

Not recommended for anything over 20 min rating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Can glass doors be used where fire ratings are required?

A

NO

unless they are tempered and meet code req.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If a wall has a 1hr rating what does the door need to be?

A

20 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

If the occupancy space is rated at 1hr, what is the door rating?

A

3/4 hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Where are lever passage sets used?

A
  • Non-sensitive areas
  • Private offices
  • Closets
  • Pantires
  • When security is not needed

Not lockng

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where are lever locksets used?

A
  • Restrooms
  • Anywhere locks are needed for a space
  • Not FR

Locking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where are locksets with panic bar AND closer used?

A
  • Required by building code
  • Assembly over 750 sqft
  • Means of egress

Locking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where are lever lockset with closers used?

A
  • FR partitions that need locking

Locking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where are lever passage set with closers used?

A
  • FR partitions that do not require locking
  • Training rooms

Not locking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Where are dummy set with magnetic latch used?

A
  • Closets and cabinets where there is no need to turn a handle

Not locking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Where are code locks with closers used?

A
  • Storage rooms
  • Copier rooms
  • Any room that needs to be secured
  • NOT usable on emergency doors

Locking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Where are lever passages sets with mag locks, closers and card readers used?

A
  • Entrances into suites

Locking

19
Q

Where are lever passage set with mag locks and door readers used?

A
  • Enterances into suites that DO NOT require FR

Locking

20
Q

What dimension are residental studs located at?

21
Q

What dimension are commerical studs located at?

22
Q

Level of Finishes

When is level 0 used?

A

Temporary construction or undetermined finish

23
Q

Level of Finishes

When is level 1 used?

A
  • Plenums above ceiling
  • Areas concleaded or not open to public traffic
24
Q

Level of Finishes

Where is level 2 use?

A
  • Backing board or substrate
  • Areas where final surface apppearance is not a concern
25
# Levels of Finishes Where is level 3 used?
* Medium or heavy textured finishes * Heavy grade wall covering
26
# Levels of Finishes Where is level 4 used?
* Flat paint * Light textures * Light wallcoverings * When budget is a concern
27
# Levels of Finishes Where is level 5 used?
* Severe lighting conditions * Gloss/semigloss enamel paints * Nontextured flat paints
28
Wood studs are how big?
* 2 x 4 * 2 x 6 | Residental or light commerical
29
Are swinging doors alllowed as an exit door?
YES | Only type of door
30
Metal studs are how big?
3 1/2" x 1 1/2" | Equivlent to 2x4
31
How thick is wallboard used in residental?
1/2"
32
How thick is wallboard used in commerical?
5/8"
33
1 hr FR rated partition is used where?
* Corridor walls * Enclosed elevator lobbies * Houses from their attached garage * Occupancy type from another in non-sprinklered bldgs * Can be used for acoustical conrol | Slab to slab single layer
34
2 hr FR rated partition is used where?
* Enlocsed vertical shafts * Stairways * Elevators * Between Assembly and Mercantile occupancy | Slab to slab double layer
35
Where are non-rated partitions used?
* Used to divide rooms within a space * Must have a min. of a 30min rating * Can be considered a smoke partition if a smoke sealant is used
36
Example of a non-rated floor-ceiling assembly
* Has no fire resistive properties * Found in a single home residential construction
37
Where does a fire barrier go from?
Deck to deck and sealed
38
What is a smoke partition?
A non-rated partition to prevent smoke from moving through teh building
39
Where is float glass used?
Where safety glass is not required
40
What type of glass can be used for FR assmemblies but NOT safety glass?
Wired glass mesh
41
What is the rating for tempered fire protective glass?
30 min
42
Can glass block be used for fire rated glass?
Yes, if it is rated
43
In a 1-HR rated wall, fire protective glazing cannot exceed what?
25% of the length of the wall
44
What are the requirements for safety glazing and door combination?
* Glass door must hav safety glazing * Windows LESS than 60" A.F.F * Windows within 24" of door * Windows MORE than 9sqft * Bottom within 18" A.F.F