CH- Chemical and Volume Control System Flashcards
What are the outlet flows of the RMWT?
alternate source for Aux. feed pumps
dilution water for RCS
water for in-plant use
What is the purpose of the boric acid batch tank?
to batch crystalline boric acid with water for adjusting boric acid concentrations in the RWT
What is the flow path for the RCP seal injection water?
Charging pumps send water through a temperature protection isolation valve, then through a HX, through two seal injection filters, and a flow control valve, then into four branches, each going to one RCP
Is the PHIX in service or bypassed when letdown is to be returned to the VCT?
bypassed
What is the temp. range of the RWT?
60-120
Where is the EDT located?
aux. building 40’
In the case of a containment isolation, where is the RCP controlled bleed off directed to via relief valve?
RDT
When valving in a CVCS ion exchanger, what is the rate at which it is valved in? How long does it take to see a change in the RCS?
slowly
7 minutes
Where is RCP seal bleed off directed to?
bleed off flow is directed to the VCT
face seal leak off is directed to the RDT
What is the purpose of the gas stripper?
removes non-condensable gases from letdown
What are the three general areas the radioactive collection, processing and storage subsystem receive water from?
letdown diverted from the VCT
RDT
EDT
What is the capacity of the reactor drain pumps?
50 gpm
What is the maximum administrative rate of cooling the RCS for CVCS to make up using 2 of 3 CH pumps?
75*F/hr
To remove boron, is anion or cation resin used?
anion
What is the purpose of the reactor drain pumps?
transfer contents from the RDT or EDT through the reactor drain filter to the PHIX
Where can the regenerative heat exchanger isolation valves be operated from?
515 and 516:
control room
remote shutdown panel
523:
from control room only
seal water expansion tank automatically makes up from where?
RMW header
Where is the RDT located?
containment 80’
In what modes of operation should the RWT be operable? What are the limit requirements?
1-4
temperature, boron concentration and volume
Where is SQN-RU-155 located?
aux building 120’ next to boronometer room
The AO can affect letdown temp. with changes in:
nuclear cooling water and plant cooling water through the nuclear cooling heat exchanger
What type of resin is used in the CVCS ion exchangers?
H-OH mixed bed
How long does it take for the delithiating ion exchanger to exhaust?
the core cycle
Where are the UV-516, -516 valves located?
100’ containment, RCP 2B pump bay entrance