Chapter 12 Flashcards
If water source is too remote ___ might be necessary
relay pumping
___________ is using two or more pumpers to move water over a long distance by operating them in series
Relay operations
A ___________ takes water from a hydrant or static source and pumps it under pressure to the next apparatus in the relay pumping operation.
Water supply pumper or Source pumper.
A ________pumper are connected within the relay that receive water from source pumper. or another relay pumper., raise the presssure and then supply next app. These can be small capacity pumps because they receive pressurized water from another pumper.
Relay pumper
_________ pumpers are located at the fire scene. the receive water and supply attack lines
Fire attack pumpers
Some depts that make many long hose lays may employ a ______tender. This app has a pump and can also carry a ______ or more of hose
hose
mile
Hose tenders will store LDH on a ______ hose bed or wound on a mechanical operated _______
traditional
reel
LDH: relay supply hose of ____ to _____ inches in diameter.
3 1/2 - 6 inches
LDH is divided into _____ and _____ line categories. Each will have diffierent working pressure limitations.
supply and attack
Relay pumping is determined by the amount of _____ required at an incident and the _____ between the incident and water source.
water
distance
The second important consideration in relay pumping the ______ of the lay.
distance.
If flow in a relay needs to be increased one of 3 things needs to happen.
- The diameter of the supply hose or number of hoselines must be increased.
- The pump discharge of the pumpers involved needs to be increased.
- More pumpers must be added to relay
Pumpers or hose tenders not in use could lay additional _____ between pumpers already in a relay operation
hose
Centrifigal pumps are rated to pump at capacity in draft at _____psi
150
If a relay has no inline valves and you want to add pumpers, the water supply must be shut down until the apps are added.
Pumpers are rated to flow their maximum volume of _____psi at draft
The flow _____% of maximum volume at 200psi
And flow _____% at 250psi
150 psi
70% at 200psi
50% at 250psi
The ______ capacity pumper is at the water source
largest
A source pumper does not have the ______ pressure of relay pumpers
residual
The overall capacity of a relay system is determined by the _____ pump and the ______ diameter hose
smallest pump
smallest diameter hose
once source pumper has established water supply, they should _______ water through a dump line until first relay pumper is ready for water.
discharge
Failure of source pumper to keep water moving could result in loss of _______
prime
A relay pumper should be waiting for water with a ____line open and the pump out of gear.
Source pumper will then close its dump line and ______open discharge to the supply line
dump
slowly
When a relay pumper receives water and a steady flow of water is discharging from the dump line, the pump may now be _____
engaged.
A relay pumper may receive water from the source pumper with the pump on if water is circulated from the onboard tank to the pump for a brief time.