Chapter 13 Flashcards
(40 cards)
The most favorable aspect of a water shuttle operation is?
The ease with which it is terminated when the incident is concluded
Per nfpa 1901 water tenders must be designed to be filled at a rate of at least what gpm?
At least 1000 gpm, pumpers at the fill site must be rated at that capacity or greater
Vehicle weight restrictions generally limit single rear axle apparatus to a maximum of what capacity?
2000 gallons
There is no need for a separate pumper at the fill site if?
You are using a vacuum tender, they are able to self-fill from a static water source at a rate of up to 2000 gpm with a lift of up to 22ft. They are also capable of discharging water at a rate of up to 1750 gpm
Faster water shuttle operations are achieved by?
Efficient filling and dumping operations, not speeding
Apparatus using medium diameter supply hose for filling should have at least how many external fill connections?
At least 2 external fill connections piped directly into the tank. If ldh is used one is generally sufficient
Legit might using ldh for filling provide little advantage?
Ldh remains particularly filled with water during each subsequent fill operation. The hose is extremely heavy and may be difficult to handle. Any advantage gained by faster fill time may be lost in longer handling times.
Nfpa 1901 requires water be capable of being dumped from?
Left right and rear of the apparatus
The two primary types of large tank discharges in use on water tenders are?
Gravity and jet assisted dumps
Driver operator must be sure that the vents are completely open during what operations?
During fill and dump operations
The dump site should be located where?
Relatively close proximity to the incident scene, but not so close where it would hamper operations or be in danger of exposure to fire or collapse
Fill and dump sites should be pre planned to what kind of locations?
Locations that allow for continual forward movement whenever possible
Streets with Two way access are also referred to as?
Through streets
What should be relayed in regards to tender location?
Must relay to the other when a tender has completed a portion of the relay and is headed in the opposite direction.
When positioning to draft at a static water supply, you should seek a position that?
Requires a minimum lift in order to maximize the flow available to supply the tender. Position to a point of best advantage for the water source
Regardless of the source what should be done by the full site pumper?
A booster line or other small discharge should be continuously flowed in the view of the driver operator
When an exact fill spot has been determined what should be done?
Place a traffic cone or similar marker to denote the stopping point for the water tender driver operator. Position this cone so that it’s adjacent to the door of the driver operator.
True or false? Using hose clamps on ldh may be unsafe. Flow through ldh should only be controlled at the pumper or with valve appliances
True
What should not be done when filling apparatus from the top?
Do not fill with a portable fill device or an open hose butt due to the reaction of the hose line and possibility of firefighters sustaining serious injuries due to falls from the top of the tender
What are firefighters at the fill site operating fill lines referred to as?
“Make and break” personnel in reference to their duties of establishing and removing connections between the water source and the tank
What should the driver/operator do when they get to a fill site?
Remain in the apparatus can to ensure peak efficiency in apparatus movement, allowing the vehicle to be moved as soon as the fill is complete and the hose is removed.
What are the three primary dumps site operational methods?
Direct pumping, nurse tender, portable water tank
Water tenders do not need to be equipped with a fire pump as long as ?
They are designed with an adequately sized direct tank discharge valve (dump valve) and proper venting.
What method is generally considered to the be the simplest and quickest method to ensure a constant water supply for fire attack operations?
Portable tank method