Chapter 3 Practice Test Flashcards
(28 cards)
What is the maximum boring percentage allowed in a load-bearing stud if doubled and not successive?
40%
2018 NCPC; NCRC P2603.2
How often must a 1” diameter Type K copper tubing be supported when run horizontally?
Every 6 feet
Table 308.5; NCRC P2605.1
How long must air and water tests of vent/drain systems be maintained at constant pressure?
15 minutes
312.2; NCRC P2503.5
1-1/2” PVC installed horizontally in commercial buildings must be supported every:
4 feet
Table 308.5; NCRC P2605.1
What is the term for the pipe that receives all discharges inside the building and leads outside?
Building drain
Chapter 2, Definition; NCRC – Chapter 2
Piping parallel to a footing must not be installed:
Closer than 6” from the footing
307.5; NCRC P2604.4
A water main is:
A public water supply pipe
Definition
Copper tubing 1-1/2”+ must be horizontally supported every:
10 feet
Table 308.5; NCRC P2605.1
Max horizontal spacing for hangers when installing cast iron pipe in 10’ sections?
10 feet
Table 308.5 Note a; NCRC P2605.1 Note a
All toilet rooms must have:
Both light and ventilation
310.1; NCRC R303
Minimum height of a urinal partition from the finished floor?
5 feet
312.2; NCRC P2503.5.1
Minimum test pressure for drainage piping?
15 psi
405.3.5
Horizontal support for 3/4” CPVC?
Every 3 feet
312.2; NCRC P2503.5.1 (3)
Rigid bracing must be used at changes >45° for pipe 4” and larger?
True
308.5; Table P2605.1
Minimum depth for exterior water service line?
306.1; NCRC P2605.1 (2)
12” or 6” below frost line.
Whichever is greater.
How must buried pipe be supported?
Throughout its entire length
305.6; NCRC P2603.2.1
Minimum cover on soil pipe leaving a building?
3”
Appendix C; NCRC R502.8.1
Minimum thickness for protective shield plates?
0.0575”
317.2; NCRC R315
Max bore in a joist is:
1/3 the depth
Appendix C; NCRC R502.8.1
When must CO alarms be installed in existing homes?
When fuel-fired appliances are replaced
317.2; NCRC R315
Max time for absence of temp toilet facilities for crews?
1 Day
311.1
Max opening size on drain inlet strainer plates?
0.5”
304.2
Which code do you refer to for fire proofing pipe through wall openings?
Building Code
307.3; NCRC R302.4.1.2
Minimum R-value for pipe insulation in unconditioned areas?
R-6.50
305.4; NCRC P2603.5