Q

Condensed Q formula for 3-inch hose.

A

FL = Q²

Answer is per 100 ft of hose

2
Q

Condensed Q formula for 4-inch hose.

A

FL = Q²/5

Answer is per 100 ft of hose

3
Q

Condensed Q formula for 5-inch hose.

A

FL = Q²/15

Answer is per 100 ft of hose