Chapter test 12/13 Flashcards
(25 cards)
TRUE OR FALSE
Lateral resolution does not improve with multi-focusing
False
On the annular phased array transducer, which part of the beam is used for the information?
Focal zone
100 x 1/1000 second= 1/10 second. What is this frame rate?
10 Hz
Temporal resolution pertains to
accuracy in time
Frame rate is determined by what 2 things
Sounds speed in the medium and the depth of imaging
Rendering creates an image from ___________ data acquired during the ultrasound exam
3D
When you excite the inner crystals and progressively excite the outer crystals to diminish lobe artifact, this is called
Apodization
TRUE OR FALSE
The sonographer can control the number of pulses in each picture
True
Sector size is also called
field of view
A sonographer increases the line density from 1 line per degree of sector to 5 lines per degree of sector. What is the most likely consequence of the action?
Temporal resolution decreases
The linear sequential array transducers have crystals that are _________ wavelength in width
1
All of the following decrease temporal resolution except:
a. deeper focusing
b. multi focus
c. lower frame rate
d. Narrower sector
Narrower sector
All of the following will cause low line density except:
a. fewer pulses per frame
b. tightly packed lines
c. higher frame rate
d. shorter T frame
Tightly packed lines
What is the unit for frame rate?
Hz
Which of the following is best described as mechanically steered and multi-focus:
a. Linear phased transducer
b. mechanical transducer
c. annular sequential array transducer
d. annular phased array transducer
annular phased array transducer
TRUE OR FALSE
Temporal resolution is reduced when few images are displayed per second
True
Is the sonographer able to change the spacing between sound beams
Yes
TRUE OR FALSE
The image shape for a convex image will be rectangle
False
With high line density, each image contains more detail, this is known as
Improved spatial resolution
A linear phased array transducer has 128 crystals, How many of these crystals are fired to create a single sound beam?
128
With a vector array images, the top of the image is
Flat
TRUE OR FALSE
When one ring of the annular array transducer malfunctions, the entire image is lost
False
Mechanical transducers have only one active element. The shape of the element resembles a
Coin
TRUE OR FALSE
When one element in a linear sequential array is damaged, only the portion of the image extending directly below the damaged element is affected
True