Economisers and Uptakes Flashcards

(3 cards)

1
Q

Explain the actions that the EOOW should take on discovering lagging on the main engine exhaust, within the funnel spaces, was on fire

A

1), Raise the Alarm - Immediate priority to alert all personnel and initiate emergency response.

2), Inform Bridge to Stop Engine - To prevent further fuel supply and combustion gases.

3), Ensure no Soot Blowing - Avoid aggravating the fire with high-velocity gases and sparks.

4), Stop Air Circulation and Cover the Turbocharger - Limit oxygen supply to the fire.

5), Shut the Inlet and Outlet Valve (Isolate the Economiser) use Bypass - Prevent fire spread.

6), Apply Boundary Cooling - Cool surrounding structure to prevent heat damage and spread.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

State TWO indications of a fire in an economiser

A
  • High Exhaust Temperature
  • Black Smoke Coming from the Funnel
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

List the course of action to be taken in the event of a fire occurring in an economiser whilst on passage

A

1), Stop the ME
2), Keep Water Circulating
3), Close Exhaust Valve
4), Cover Turbocharger
5), Use Water Washing to Fight Fire
6), Apply Boundary Cooling

How well did you know this?
1
Not at all
2
3
4
5
Perfectly