Electrical Flashcards
(30 cards)
AC power is provided by what sources?
Engine-driven generators
APU generator
External power
DC power is provided by what sources?
Main battery
APU battery
TRUs
What are the two subcomponents of the IDGs?
Constant Speed Drive (CSD)
40 kVA generator
Once the IDG has been disconnected, can it be reconnected in the air?
No, only maintenance can reconnect
What faults will cause the IDG switch light to illuminate?
Low oil pressure & high oil temperature (hot lop)
The IDG will automatically disconnect with what two conditions?
Over torque & over temperature
Generator fault protection is provided for what?
Under/over voltage
Under/over frequency
Out of phase
With the external power on the aircraft, what will happen when an engine driven generator comes online?
The external power switch light changes from white IN USE to green AVAIL.
The engine-driven generator will then pick up the entire load.
What is the purpose of the AC switch light on the external service panel?
Powers the AC Service Bus
Provides dome and lavatory lights
Electrical outlets in the cabin
Cleaning and maintenance switch light.
When will the AC ESS XFER light be illuminated?
When the AC ESS BUS is being powered by BUS 2
What is the power source priority for AC Bus 1?
GEN 1
APU GEN
GEN 2
EXTERNAL AC
What would happen if a Bus fault condition were to occur on either AC Bus 1 or AC Bus 2?
The associated generator would be taken offline.
Would the AC Bus be transferred to the next generator in line?
No, the AUTO XFER FAIL switch light will illuminate, preventing auto transfer.
When will the ADG automatically deploy?
When any generator has been online.
AC Buses 1 and 2 become unpowered.
Weight off wheels.
Once the ADG is deployed, what will it power?
AC ESS BUS.
Hydraulic pump 3B.
Slats and flaps.
Pitch trim channel 2.
Below what speed will the ADG be unable to provide power?
135 kts.
Why must you physically pull the ADG Handle to deploy, when doing the EMER POWER QRH?
To close the emergency tie contactors allowing the DC Essential Bus to remain powered by batteries after landing.
Following ADG deployment, how can a generator be selected if it once again becomes operational?
By pushing the PWR TZFR OVERRIDE button.
How many TRUs? Each is rated at how many amps?
Four at 120 amps.
What do TRUs do?
They convert 115-volt AC power into 28-volt DC power.
The APU battery is rated at ______ amps.
43
The main battery is rated at ____ amps.
17
How long can the batteries provide power in the event of total electrical failure?
30 minutes
When will the main bus tie automatically close?
Anytime TRU 1 or 2 fails