Electrical Flashcards

(36 cards)

1
Q

Main Generator ratings

A

30/45 kVA, 115 volt ac, 3 phase, 400 hz

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Main driven by___

A

Accessory modules

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Lubrication for main gen

A

transmission oil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

APU Generator ratings

A

35 kVA, 115 volt ac, 3 phase, 400 hz

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Generator control unit functions

A
Connects each generator to ac bus system
Regulates generator output
Protects against
         overvoltage
         undervoltage
         feeder fault
         underfrequency
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

WOW GCU disconnects main generator from power distribution at____

A

94% Nr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In flight underfrequency protection disabled and generators remain online until _____

A

80% Nr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Minimum Nr for GCU to reconnect generators

A

97% Nr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What can external power provide when its the sole source

A

Energize the entire system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

External power circuit breaker and current draw

A

4 amp circuit breaker

2 amp draw on the cable, some ships require a load to be sensed in order to apply power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

5 AC buses

A
#1 AC Primary
#2 AC Primary
AC Essential
AC secondary
AC Monitor
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What happens to external power when either a main or apu is on

A

Automatically disconnects

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

No. 1 Generator powers what buses

A

1 AC primary

AC essential
AC secondary

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

No. 2 Generator powers what buses

A
#2 AC primary
AC monitor
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If APU on with both mains on

A

APU will not be connected to the AC bus distribution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Major load on No.1 AC Primary

A

Backup hyd pump

17
Q

Major load on AC secondary

A

Mission pwr avionics

Tail rotor deice

18
Q

Major and only load on AC monitor

A

Main rotor Deice

19
Q

Buses powered with only APU

A
#1 AC primary
#2 AC primary
AC Essential
20
Q

Only One Gen and APU with bakcup and mission pwr on

A

AC Monitor will not be powered

21
Q

Only one Gen

A

AC SEC and AC MON will not be powered

22
Q

Number of converters and power supply

A

2 converters, 28 Vdc

23
Q

Power to converters from

A

1/2 AC primary bus

24
Q

Power of battery, composition

A

24 Vdc

Nickel-cadmium

25
Battery, primary source of power for?
APU start
26
Battery, secondary source for
DC essential and battery bus
27
Battery life with 80% charge
11 minutes day | 9 minutes night
28
Normal operations battery powers?
Battery utility bus
29
Battery analyzer/conditioner monitoring powered by?
#2 AC primary bus
30
Battery analyzer/conditioner monitors for?
Fault conditions Battery charge internal temp cell conditions
31
Battery analyzer/conditioner charges battery through?
2 DC primary bus
32
1 converter powers
#1 DC primary DC essential battery bus
33
#2 converter powers
#2 DC Primary
34
Single converter failure
Other converter picks up load
35
Dual converter failure, battery powers
``` utility bus battery bus (if switch on) DC essential (charge above 35%) ```
36
Battery below___ and no other source of power may not have sufficient fire bottle CAD
30%