Elevations Flashcards

(45 cards)

1
Q

Draft tube access gallery / runner hub drain header

A

367

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Maximum tail water

A

444

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Crane access balcony

A

457 assembly bay + 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Minimum tailwater for navigation

A

385

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Minimum headwater

A

442

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Center of switchyard / top of powerhouse parapet

A

496

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Centerline of scroll case and wicket gates

A

395

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Bottom of station sump

A

348

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Unwatering sump water level alarm sounds / unwatering sump pumps start (manually)

A

340

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Bottom of draft tube

A

335

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Spillway crest

A

406

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Intake to scroll case backfill

A

430

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Classroom roof

A

464 top of dam + 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Bottom of Unwatering Sump

A

326

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Top of trash racks

A

420

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Pump floor

A

414.75 Generator cooling water pump Unwatering pumps Governor oil accumulator tank Generator emergency cooling water pump Governor oil pump and sump Deluge fire pump Access to elev 428

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Turbine floor

A

413-Elevator storage room Heavy equipment room Water treatment room Oil storage room Oil purification room Access to station sump pump floor Oil storage and purification CO2 Raw service water pumps Farval greasers Access to thrust housing Access to wheel pit Access to scroll case door Access to Unwatering valve room Warehouse transformer 1 and 2 Generator CO2 equipment Spread room Cable gallery Generator surge protection equipment Air compressors ( station service, evacuation, governor ) Air receiver tanks ( station service, evacuation, brake, governor )

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Top of dam

A

463

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Station sump pump discharge to tailwater

20
Q

Generator floor

A

428 Machine shop Electric shop Electric storage room Break room Switchgear room # 1 Control room Switchgear room # 2 Battery room MG room Fan room # 2 Emergency diesel room Fan room # 3 Restrooms

21
Q

Station sump pump room floor

22
Q

Top of classroom roof parapet

23
Q

Top of Powerhouse Crain Rail

24
Q

Generator cooling water intake

25
Bottom of spillway bucket
372
26
Emergency cooling water intake / raw water intake
410
27
Tail deck
418
28
Center of Generator Shaft Coupling
416
29
Spillway bulkhead storage/spillway gate machinery compartments
455
30
Maximum headwater
450
31
Transformer yard
447 Parking plaza Service bay erection area Service bay erection area storage Visitors lobby Office area Communication room File room Fan room # 1 Classroom Top of spillway gates
32
Depressed water level
375
33
Minimum Tailwater / Top of Spillway Bucket
382
34
Intake deck
452 max HW + 2
35
Normal headwater
445
36
Oil circuit breaker bases
496.5
37
Side of switchyard
495.75
38
Intake to tailwater gage well
380
39
Excavation for unwatering sump (lowest elevation)
323
40
Centerline of spillway gate trunions
425
41
Bottom of Trash Rack
374
42
Valve Room for Unwatering Valves
400.5
43
Clean and Dirty Lube Oil Pumps and Purifier
410.5
44
Lock Operating Building
455.5
45
Thrust Housing Floor
420.5