Name Plates Flashcards Preview

Hydropower > Name Plates > Flashcards

Flashcards in Name Plates Deck (225)
Loading flashcards...
1
Q

Main Generator Manufacturer

A

General Electric

2
Q

Main Exciter Manufacturer

A

General Electric

3
Q

Pilot Exciter Manufacturer

A

General Electric

4
Q

PMG-Permanent Magnet Generator Manufacturer

A

Woodward

5
Q

Turbine Manufacturer

A

Baldwin Lima Hamilton Corp

6
Q

Governor Oil Pump Manufacturer

A

Woodward

7
Q

Governor Oil Pump Motor Manufacturer

A

General Electric

8
Q

AC Turbine Bearing Oil Pump Manufacturer

A

Roper

9
Q

AC Turbine Bearing Oil Pump Motor Manufacturer

A

Master Electric

10
Q

Generator Neutral Breaker Manufacturer

A

Allis Chalmers

11
Q

Generator Field Breaker Manufacturer

A

General Electric

12
Q

Generator Vacuum Breaker Manufacturer

A

Eaton

13
Q

DC Turbine Bearing Oil Pump Manufacturer

A

Roper

14
Q

DC Turbine Bearing Oil Pump Motor Manufacturer

A

Master Electric

15
Q

Diesel Generator Manufacturer

A

General Motors

16
Q

Diesel Motor Manufacturer

A

General Motors Detroit Diesel

17
Q

Station Sump Pump Manufacturer

A

Flygt

18
Q

Station Sump Pump Motor Manufacturer

A

Flygt

19
Q

Deluge Fire Pump Manufacturer

A

Aurora

20
Q

Deluge Fire Pump Motor Manufacturer

A

Lincoln

21
Q

Service Water Pump Manufacturer

A

Buffalo

22
Q

Service Water Pump Motor Manufacturer

A

General Electric

23
Q

AC Headcover Sump Pump Manufacturer

A

Gorman Rupp

24
Q

AC Headcover Sump Pump Motor Manufacturer

A

Marathon Electric

25
Q

DC Headcover Sump Pump Manufacturer

A

Gorman Rupp

26
Q

DC Headcover Sump Pump Motor Manufacturer

A

Master Electric

27
Q

Farval Greaser Pump Manufacturer

A

Farval

28
Q

Farval Greaser Pump Motor Manufacturer

A

Baldor

29
Q

Unit Cooling Water Pump Manufacturer

A

Bell and Gossett

30
Q

Unit Cooling Water Pump Motor Manufacturer

A

Baldor Reliance

31
Q

Emergency Cooling Water Pump Manufacturer

A

Bell and Gossett

32
Q

Emergency Cooling Water Pump Motor Manufacturer

A

Baldor Reliance

33
Q

Supervisory Battery Manufacturer

A

Varta

34
Q

Supervisory Battery Charger Manufacturer

A

GNB

35
Q

Station Battery Manufacturer

A

Power Safe

36
Q

Station Battery Charger Manufacturer

A

GNB

37
Q

Inverter Set Manufacturer

A

LaMarche

38
Q

Governor Air Compressor Manufacturer

A

Quincy

39
Q

Governor Air Compressor Motor Manufacturer

A

Baldor Reliance

40
Q

Station Service Air Compressor Manufacturer

A

Gardner Denver

41
Q

Station Service Air Compressor Motor Manufacturer

A

Toshiba

42
Q

Evacuation Air Compressor Manufacturer

A

Gardner Denver

43
Q

Evacuation Air Compressor Motor Manufacturer

A

Toshiba

44
Q

Main Transformer Manufacturer

A

Westinghouse

45
Q

Main Transformer Current Limiting Reactor Manufacturer

A

Westinghouse

46
Q

North Bank Transformer 1 Manufacturer

A

Balteau Standard Inc

47
Q

North Bank Transformer 2 Manufacturer

A

Niagara

48
Q

Spillway Gate Motor Manufacturer

A

Louis Allis

49
Q

Spillway Gate High Speed Gear Box Manufacturer

A

Foote Bros Gear and Machine Co

50
Q

Spillway Gate Low Speed Gear Box Manufacturer

A

Western Gear Works

51
Q

Oil Circuit Breaker Manufacturer

A

General Electric

52
Q

Station Service Transformer Manufacturer

A

Sorgel

53
Q

Lighting Transformer Manufacturer

A

Hevi Duty Electric

54
Q

Warehouse Transformer 1 Manufacturer

A

Cutler Hammer

55
Q

Warehouse Transformer 2 Manufacturer

A

Cutler Hammer

56
Q

Lubricating Oil Transfer Pump Manufacturer

A

Viking

57
Q

Lubricating Oil Transfer Pump Motor Manufacturer

A

Fairbanks Morse

58
Q

Oil Purification Pump Manufacturer

A

DeLaval

59
Q

Oil Purification Pump Motor Manufacturer

A

Lewis Allis

60
Q

Insulating Oil Transfer Pump Manufacturer

A

Viking

61
Q

Insulating Oil Transfer Pump Motor Manufacturer

A

Fairbanks Morse

62
Q

Unwatering Pump Manufacturer

A

American Marsh

63
Q

Unwatering Pump Motor Manufacturer

A

Nidec Motor Corp

64
Q

Turbine Horsepower

A

35000

65
Q

Governor Oil Pump Motor Horsepower

A

75

66
Q

AC Turbine Bearing Oil Pump Motor Horsepower

A

0.5

67
Q

DC Turbine Bearing Oil Pump Motor Horsepower

A

0.5

68
Q

Diesel Motor Horsepower

A

280

69
Q

Station Sump Pump Motor Horsepower

A

20

70
Q

Deluge Fire Pump Motor Horsepower

A

60

71
Q

Service Water Pump Motor Horsepower

A

40

72
Q

AC Headcover Sump Pump Motor Horsepower

A

0.5

73
Q

DC Headcover Sump Pump Motor Horsepower

A

0.5

74
Q

Farval Greaser Pump Motor Horsepower

A

0.5

75
Q

Unit Cooling Water Pump Motor Horsepower

A

15

76
Q

Emergency Cooling Water Pump Motor Horsepower

A

20

77
Q

Governor Air Compressor Motor Horsepower

A

10

78
Q

Station Service Air Compressor Motor Horsepower

A

30

79
Q

Evacuation Air Compressor Motor Horsepower

A

75

80
Q

Spillway Gate Motor Horsepower

A

10

81
Q

Spillway Gate High Speed Gear Box Horsepower

A

service HP 13.1

82
Q

Spillway Gate Low Speed Gear Box Horsepower

A

4.7

83
Q

Lubricating Oil Transfer Pump Motor Horsepower

A

3

84
Q

Oil Purification Pump Motor Horsepower

A

2

85
Q

Insulating Oil Transfer Pump Motor Horsepower

A

10

86
Q

Unwatering Pump Motor Horsepower

A

125

87
Q

Main Generator RPM

A

75

88
Q

Main Exciter RPM

A

75

89
Q

Pilot Exciter RPM

A

75

90
Q

PMG-Permanent Magnet Generator RPM

A

75

91
Q

Turbine RPM

A

75

92
Q

Governor Oil Pump RPM

A

700

93
Q

Governor Oil Pump Motor RPM

A

700

94
Q

AC Turbine Bearing Oil Pump RPM

A

1140

95
Q

AC Turbine Bearing Oil Pump Motor RPM

A

1140

96
Q

DC Turbine Bearing Oil Pump RPM

A

1140

97
Q

DC Turbine Bearing Oil Pump Motor RPM

A

1140

98
Q

Diesel Generator RPM

A

1800

99
Q

Diesel Motor RPM

A

1800

100
Q

Station Sump Pump RPM

A

1750

101
Q

Station Sump Pump Motor RPM

A

1750

102
Q

Deluge Fire Pump RPM

A

1775

103
Q

Deluge Fire Pump Motor RPM

A

1775

104
Q

Service Water Pump RPM

A

1765

105
Q

Service Water Pump Motor RPM

A

1765

106
Q

AC Headcover Sump Pump RPM

A

3450

107
Q

AC Headcover Sump Pump Motor RPM

A

3450

108
Q

DC Headcover Sump Pump RPM

A

1725

109
Q

DC Headcover Sump Pump Motor RPM

A

1725

110
Q

Farval Greaser Pump RPM

A

1725

111
Q

Farval Greaser Pump Motor RPM

A

1725

112
Q

Unit Cooling Water Pump RPM

A

1800

113
Q

Unit Cooling Water Pump Motor RPM

A

1765

114
Q

Emergency Cooling Water Pump RPM

A

1800

115
Q

Emergency Cooling Water Pump Motor RPM

A

1765

116
Q

Governor Air Compressor RPM

A

1770

117
Q

Governor Air Compressor Motor RPM

A

1770

118
Q

Station Service Air Compressor RPM

A

1770

119
Q

Station Service Air Compressor Motor RPM

A

1770

120
Q

Evacuation Air Compressor RPM

A

1765

121
Q

Evacuation Air Compressor Motor RPM

A

1765

122
Q

Spillway Gate Motor RPM

A

1690

123
Q

Spillway Gate High Speed Gear Box RPM

A

Imput 1750

124
Q

Spillway Gate Low Speed Gear Box RPM

A

152 pinion

125
Q

Lubricating Oil Transfer Pump RPM

A

1745

126
Q

Lubricating Oil Transfer Pump Motor RPM

A

1745

127
Q

Oil Purification Pump RPM

A

1740

128
Q

Oil Purification Pump Motor RPM

A

1740

129
Q

Insulating Oil Transfer Pump RPM

A

1740

130
Q

Insulating Oil Transfer Pump Motor RPM

A

1740

131
Q

Unwatering Pump RPM

A

1785

132
Q

Unwatering Pump Motor RPM

A

1785

133
Q

Main Transformer Gal of Oil

A

4900

134
Q

Main Transformer Current Limiting Reactor Gal of Oil

A

156

135
Q

North Bank Transformer 1 Gal of Oil

A

160

136
Q

North Bank Transformer 2 Gal of Oil

A

164

137
Q

Oil Circuit Breaker Gal of Oil

A

231

138
Q

Main Generator KW

A

25000

139
Q

Main Exciter KW

A

300

140
Q

Pilot Exciter KW

A

17

141
Q

Diesel Generator KW

A

150

142
Q

Main Generator Volts

A

13800

143
Q

Main Exciter Volts

A

250 full load

144
Q

Pilot Exciter Volts

A

250 full load

145
Q

PMG-Permanent Magnet Generator Volts

A

66 full load

146
Q

Governor Oil Pump Motor Volts

A

440

147
Q

AC Turbine Bearing Oil Pump Motor Volts

A

220/440

148
Q

Generator Neutral Breaker Volts

A

rated V 13800

149
Q

Generator Field Breaker Volts

A

DC V 250

150
Q

Generator Vacuum Breaker Volts

A

rated Max V 15000

151
Q

DC Turbine Bearing Oil Pump Motor Volts

A

125

152
Q

Diesel Generator Volts

A

480

153
Q

Station Sump Pump Motor Volts

A

230/460

154
Q

Deluge Fire Pump Motor Volts

A

230/460

155
Q

Service Water Pump Motor Volts

A

220/440

156
Q

AC Headcover Sump Pump Motor Volts

A

208-230/440

157
Q

DC Headcover Sump Pump Motor Volts

A

125

158
Q

Farval Greaser Pump Motor Volts

A

115/230

159
Q

Unit Cooling Water Pump Motor Volts

A

230/460

160
Q

Emergency Cooling Water Pump Motor Volts

A

230/460

161
Q

Supervisory Battery Volts

A

2.23 V per cell

162
Q

Supervisory Battery Charger Volts

A

Input 480 V AC output 48 V DC

163
Q

Station Battery Volts

A

2.23 V per cell

164
Q

Station Battery Charger Volts

A

Input 480 V AC output 130 V DC

165
Q

Inverter Set Volts

A

Input 120 V DC output 120 V AC

166
Q

Governor Air Compressor Motor Volts

A

230/460

167
Q

Station Service Air Compressor Motor Volts

A

230/460

168
Q

Evacuation Air Compressor Motor Volts

A

230/460

169
Q

Main Transformer Volts

A

HS 69000 LS 13200

170
Q

Main Transformer Current Limiting Reactor Volts

A

16100

171
Q

North Bank Transformer 1 Volts

A

HS 13800 LS 4160/2400

172
Q

North Bank Transformer 2 Volts

A

HS 13800 LS 4160/2400

173
Q

Spillway Gate Motor Volts

A

440

174
Q

Oil Circuit Breaker Volts

A

rated V 69000

175
Q

Station Service Transformer Volts

A

HS 13800 LS 480

176
Q

Lighting Transformer Volts

A

HS 480 LS 208/120

177
Q

Warehouse Transformer 1 Volts

A

HS13800 LS 2400

178
Q

Warehouse Transformer 2 Volts

A

HS13800 LS 2400

179
Q

Lubricating Oil Transfer Pump Motor Volts

A

220/440

180
Q

Oil Purification Pump Motor Volts

A

220/440

181
Q

Insulating Oil Transfer Pump Motor Volts

A

220/440

182
Q

Unwatering Pump Motor Volts

A

460

183
Q

Main Generator Number of Poles

A

96

184
Q

Main Exciter Number of Poles

A

10

185
Q

Pilot Exciter Number of Poles

A

6

186
Q

PMG-Permanent Magnet Generator Number of Poles

A

12 pole characteristic

187
Q

Generator Field Breaker Number of Poles

A

2

188
Q

Turbine Head

A

45

189
Q

Station Sump Pump Head

A

92

190
Q

Deluge Fire Pump Head

A

196

191
Q

Service Water Pump Head

A

231

192
Q

Unit Cooling Water Pump Head

A

45.5

193
Q

Emergency Cooling Water Pump Head

A

58

194
Q

Unwatering Pump Head

A

92

195
Q

Governor Oil Pump Gal Per Min

A

300

196
Q

Station Sump Pump Gal Per Min

A

300

197
Q

Deluge Fire Pump Gal Per Min

A

750

198
Q

Service Water Pump Gal Per Min

A

300

199
Q

Unit Cooling Water Pump Gal Per Min

A

900

200
Q

Emergency Cooling Water Pump Gal Per Min

A

900

201
Q

Lubricating Oil Transfer Pump Gal Per Min

A

30

202
Q

Oil Purification Pump Gal Per Hr

A

300-350 GPH

203
Q

Insulating Oil Transfer Pump Gal Per Min

A

100

204
Q

Unwatering Pump Gal Per Min

A

3500

205
Q

Governor Oil Pump PSI

A

300

206
Q

Governor Air Compressor PSI

A

200-500 range 300 operating

207
Q

Station Service Air Compressor PSI

A

125

208
Q

Evacuation Air Compressor PSI

A

125

209
Q

Lubricating Oil Transfer Pump PSI

A

65

210
Q

Insulating Oil Transfer Pump PSI

A

120

211
Q

Governor Oil Pump Type

A

Type XX Herringbone Gear Positive Displacement

212
Q

AC Turbine Bearing Oil Pump Type

A

Gear Type Positive Displacement

213
Q

DC Turbine Bearing Oil Pump Type

A

Gear Type Positive Displacement

214
Q

Station Sump Pump Type

A

centrifugal

215
Q

Deluge Fire Pump Type

A

centrifugal

216
Q

Service Water Pump Type

A

centrifugal

217
Q

AC Headcover Sump Pump Type

A

centrifugal

218
Q

DC Headcover Sump Pump Type

A

centrifugal

219
Q

Unit Cooling Water Pump Type

A

centrifugal

220
Q

Emergency Cooling Water Pump Type

A

centrifugal

221
Q

Governor Air Compressor Type

A

double stage single action

222
Q

Station Service Air Compressor Type

A

screw

223
Q

Evacuation Air Compressor Type

A

screw

224
Q

Oil Purification Pump Type

A

centrifugal

225
Q

Unwatering Pump Type

A

centrifugal

Decks in Hydropower Class (81):