Engine Company Equipment Chap3 Flashcards

(52 cards)

1
Q

1 3/4 hose
What size coupling?
Normal operating pressure is?
Friction loss for each 50 foot length of 1 3/4 hose is?
2.2.3

A

1 1/2
250 psi
20 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which size hose is considered most versatile? 2.3.1.

A

2 1/2 inch
It can be a supply line or an attack line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

2 1/2 hose.
Coupling size?
Operating pressure is normally limited to ?
Friction loss is ?
2.3.4

A

2 1/2
250 psi
5 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

T/F The 2 inch lightweight hose is only used as the lead length on the attack line when using a standpipe system in residential buildings 2.4.3

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

2 inch lightweight hose.
Coupling size is?
Normal operating pressure is limited to?
Friction loss for each length?
Midpoint is painted what color and is called ?
Reflective arrows on each —- coupling that serve as a directional indicator the arrow points in the direction of the water source.
2.4.4

A

Coupling 2 1/2
Pressure 250 psi
Friction loss per length 10 psi
Red known as A Fold
Female

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

2 1/2 inch lightweight hose.
Color is?
It is to use —- line when using a standby system?
Coupling size?
Operating pressure is normally?
Friction loss for each length is?
Midpoint painted ?
This marking can facilitate a smoother deployment of the hose and it’s called the? 2.5.4.

A

White with red stripes
Attack line
Coupling size is 2 1/2 inch
Operating pressure is normally limited to 250 psi.
Friction loss is 5 psi
Midpoint painted red
A fold

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

3 1/2 inch hose.
Is only used as a?
Coupling size?
Operating pressure is normally limited to?
Friction loss for each length approximately?
2.6.3

A

Supply line
Coupling size 3 inch
300 psi
3 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

OST TIp is what size? And should only be attached to. —— for overhaul operations, if team necessary
3.4.2 B

A

1/2
MST
Only for Overhaul

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

1 3/4 nozzle.
Required nozzle pressure is?
At 50 psi nozzle pressure the flow rate is?
The 1/2 OST can be attached to the MST for?

A

50 psi at the tip
Flow rate is 180 gallons per minute
Overhaul purposes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

2 1/2 inch nozzle.
Required nozzle pressure is?
The flow rate is —— GPM if you use the same psi as above.
The 1/2 OST can be attached to MST for?
3.6.3

A

40 psi at the tip
Flow rate 235 gallons per minute at 40 psi
Overhaul purposes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

2 1/2 inch nozzle should be marked with? 3.6.3

A

A white stripe around the MST.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

2 inch nozzle.
It is used with what type hose?
Coupling size?
Tip size ——MST for attack?
Nozzle pressure is?
3.6.4

A

2 inch lightweight hose
2 1/2 inch coupling.
1 inch MST tip
50 psi at the tip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fog nozzles the straight stream is ——? 3.7.1.

A

Hollow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Fog patterns are effective for maximizing —— ventilation, dispersing, gas, vapors, and extinguishing fire near —- Equipment.
3.7.3

A

Hydraulic ventilation
Electrical equipment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

1 3/4 Fog nozzle. To operate as a straight stream the tip is rotated to the. ——?
3.7.5 G

A

Right

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

1 3/4 fog nozzle to operate as a fog pattern, the tip is rotated to the——.
3.7.5 H

A

Left

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

1 3/4 fog nozzle the further to the left, the tip is rotated the ——- fog pattern will be?
3.7.5 I

A

Wider

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

The combination nozzle is considered a —- piece system.
3.7.11

A

Two piece
But is comprised of three different components.
Base pipe
High-rise nozzle
Cockloft nozzle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is permanently attached to the
Base pipe of the combination nozzle?

A

2 1/2 inch shut off (permanently attached)
and has a 1 1/2 quick connect for attaching one of the two different nozzles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Cockloft nozzle tip, each bend terminates with a —— and ——.
3.7.11 C

A

15/16” MST and 1/2 OST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

The cockloft nozzle tip has two 1/2” OST’s are not to be removed. These tips increase the rate of the stream in excess of. ——
3.7.11 C

A

60 feet.
They also facilitate the generation of STEAM that enables a more rapid extinguishment of the fire in the confined spaces of the cockloft.

22
Q

T/F
The original one piece HRN has not been removed from companies equipped with the combination nozzle. These companies carry both so the non-train members can use the one piece HRN. Engine companies not trained in the use of the combination nozzle system should continue to use the conventional high-rise nozzle or cockloft nozzle as required . 3.7.11 page 18.

23
Q

Bent tip can be supplied by?
PSI at tip?
3.7.12

A

1 3/4 or 2 1/2
50 psi

24
Q

The bent tip is equipped with a hand lever that can be used to rotate the nozzle?
3.7.12
NEW

25
The bent tip is designed to extinguish fire in? 3.7.12
Confined spaces, such as ducts Shafts Void spaces between walls, floors and ceilings. Including cockloft.
26
T/F Digital In-line pressure gauge it is used to regulate water flow. 6.1.1.
False It does not regulate water flow. It’s simply monitors the pressure and flow of water supplied.
27
The digital in-line gauge has 2 1/2”couplings and a built-in? 6.1.2
45° elbow
28
The digital in-line gauge, how do you turn it on 6.1.3
FIRMLY press and hold the green on/off button. The digital display will show 0 pressure and 0 flow now ready for use.
29
The digital in-line pressure gauge. The red digital display shows the? 6.1.4
Pressure at the gauge in psi
30
Digital in-line pressure gauge. High pressure warning: red displays flashing —- when pressure exceeds—- psi. 6.1.4.
“HI-P” Exceeds 200 psi
31
Digital in-line pressure gauge. The blue digital display shows water flow——? 6.1.5
GPM
32
Digital in-line pressure gauge high flow warning: blue dis —— when the flow exceeds —- gallons per minute : Blue displays flash —- when the flow is less than — gpm. 6.1.5
“ HI-F” Exceeds 250 GPM “LO-F”. Less than. 80 GPM
33
Digital in-line pressure gauge if there’s no water flow —- minutes display goes into —— mode and will not display readings 6.1.6
15 minutes Sleep mode
34
Digital in-line pressure gauge if there is no water flow — minutes the display will ———. 6.1.6.
30 minutes Power off automatically. To resume operations, the gauge has to be restarted manually.
35
T/F The digital in-line gauge is powered by AAA rechargeable lithium ion batteries, only the supplied batteries may be used. 6.1.7.
False SPECIAL 9V rechargeable, lithium, ion batteries
36
Digital in-line pressure gauge a fully charged battery will be approximately — hours of continuous operation. 6.1.7
5 hours
37
Digital in-line gauge after— hours of usage, the digital display was slowly flash “LO BATT” 6.1.7
3 1/2 hours
38
In-line digital pressure gauge —- minutes of battery life remains “LO BATT” will flash rapidly. Immediately replace the batteries if this occurs 6.1.7.D
10 minutes
39
In-line digital pressure gauge, units are issued — batteries. 6.1.7 F
4 batteries
40
In-line digital pressure gauge has four batteries, where are they kept? 6.1.7.
1 in the gauge 1 carried in CLEAR battery pouch of the carrying case 2 in the charging unit at quarters.
41
In-line digital pressure gauge batteries on the charger should be rotated —— and switched with the batteries in the gauge and the carrying case. 3.1.7 G
Weekly
42
Digital in-line pressure gauge the battery charger indicators are as follows: Steady red color Slowly, blinking red color Steady Green? 6.1.7 H PS notice there’s no yellow color
Battery is charging Battery is defective must be replaced Fully charge battery
43
The foam nozzle can be identified by? 7.2
White markings on the tip handle pistol grip
44
When the foam nozzle is supplied with 200 psi, it will flow at —- GPM. 7.3
125 GPM
45
The New Yorker Multiversal. Has three size tips? What is the psi that correlates with those tips? 8.2
1 1/4. 100 psi 1 1/2. 70 psi 2”. 50 psi ACRO 10-75
46
The New Yorker Multiverse has two 3 inch inlets the max pressure to be supplied to the appliance space is. 8.3
200 psi
47
Bresnan distributor distributes water in a 360° pattern. It is designed to be used remotely in a fire area that cannot be accessed by a hoseline. Generally, it is used for fires ——. 10.1.
Fire below grade, such as cellars.
48
The Bresnan distributor is supplied with — hose. A shut off should be placed ———- allowing the flow to be controlled. 10.4.
2 1/2 hose 1 length from distributor
49
T/F The Bresnan distributor should be lowered into the Fire area via an opening and the shut off should be opened to begin with a flow. The distributor is lowered until it hits the floor, then raised SEVERAL feet to position for optimal distribution. 10.5.
True
50
Curb valves key which direction do you turn the operating nut to close 17.2
Counterclockwise to close. This is opposite of the righty tighty lefty Loosey rule.
51
1 3/4 and 2 1/2 normal operating pressure is ?
250psi 250psi
52
Friction Loss 1 3/4 hose 2” light weight hose 2 1/2 hose 2 1/2 light weight hose
20psi 10psi 5psi 5psi