Engine Company Handbook Flashcards
Engine Company Handbook
All Sacramento Fire engine apparatus meet the specifications and standards as outlined by the NFPA __________________.
1901-Standard for Automotive Fire Apparatus
Engine Company Handbook
Sacramento Fire engines have permanently mounted centrifugal fire pumps which can produce up to __________ their rated capacity with adequate water supply from a hydrant.
twice
Engine Company Handbook
Securing a water supply is a top priority but does not supersede the need to establish an ___________________.
interior attack hose line
Engine Company Handbook
The hose beds on a Sacramento Fire engine are configured to perform both ________ and __________ operations.
supply / fire attack
Engine Company Handbook
Each engine has two ___ inch intakes equipped with a ball-intake valve.
6
Engine Company Handbook
All engines have a permanently mounted fire pump with a rated discharge capacity of at least ____ gpm.
1,000
Engine Company Handbook
On a Type VI unit, how many gallons does the water tank hold?
400
Engine Company Handbook
How much 3” hose is in a flat load on a Type 1 engine?
600
Engine Company Handbook
The primary mission of an engine is to provide ______ ________ for fire streams.
adequate pressure
Engine Company Handbook
The Dash class engine is outfitted with a ________ pump, while the Velocity and the Enforcer classes are outfitted with a _______ pump
two-stage / single stage
Engine Company Handbook
All of the hose used by Sacramento Fire meets the requirements set forth by the NFPA _________.
1961-Standard on Fire Hose
Engine Company Handbook
In the three-inch hose bed, small hand loops will be placed every _______ on the _______ stack.
50’ / right
Engine Company Handbook
The primary causes of damage to fire hose are _______, _______, and ________.
mechanical / thermal/ chemical
Engine Company Handbook
The polyester hose jacket can melt in the range of ______.
500 F
Engine Company Handbook
Have the Sacramento Fire Hose Shop service-test hose if there is suspicion of a ________ exposure.
chemical
Engine Company Handbook
After such chemical exposures, hose must be thoroughly washed as soon as possible with _______, _______ water.
warm, soapy
Engine Company Handbook
The two primary types of hose couplings used by the Sacramento Fire are ________ and _________.
threaded / Storz
Engine Company Handbook
National Pipe Straight Hose (NPSH), also known as “pipe thread”, is used on __________ hose.
1” forestry
Engine Company Handbook
To ensure each section of hose is eventually rotated throughout the entire hose bed, the _________ method will be followed.
“first-to-last”
Engine Company Handbook
Remove _______ and ______ from the hose before placing it back into hose beds as this is a leading cause to the breakdown of the fibers in the jacket.
dirt / grit
Engine Company Handbook
When hose is sent in for repair, place an ______ next to its inventory number in the “Hose Rack” box.
“x”
Engine Company Handbook
Company officers are responsible for ensuring that newly received hose undergoes the _______ ______ process.
service test
Engine Company Handbook
All fire hose will undergo service testing on an _______ basis and after any ________ are made.
annual / repairs
Engine Company Handbook
Maximum length of hose to be tested per engine outlet is ______ feet.
300