Fixtures, Faucets and Fixture Fittings Flashcards
Chapter 4 (48 cards)
What type of urinal is prohibited?
Trough Urinals
Sheet copper for general applications shall conform to ASTM B152 and shall not weigh less than _______ ounces per square foot.
12 ounces
Sheet lead for pans shall not weigh less than _______ pounds per square foot.
4 pounds
On what page can the table for minimum number of required plumbing fixtures be found?
Page 23
For attached one and two-family dwellings, one automatic clothes washer connection shall be required per ______ dwelling units.
20
For fixture calculation purposes, how do you determine the occupant load of each sex?
Divide total occupant load in half.
Separate facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of ______ or fewer.
25
Separate facilities shall not be required in mercantile occupancies in which the maximum occupant load is _____ or fewer.
100
Public toilet facilities shall be required in open or enclosed parking garages where there are no parking attendants.
True or False
False
Public toilet facilities are not required in structures and tenant spaces intended for quick transactions, including takeout, pickup and drop-off, having a public access area less than or equal to ______ square feet.
300
Where are routes to public toilet facilities prohibited?
Routes that pass through kitchens, storage rooms or closets.
In occupancies other than covered and open mall buildings, the required public and employee toilet facilities shall be located not more than _______(1) above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of ______(2) feet.
(1) One Story
(2) 500 feet
Facilities that are required for employees in storage structures or kiosks, and are located in adjacent structures under the same ownership, lease or control, shall be a maximum travel distance of ______ feet from the employees’ working area.
500 feet
What is the maximum travel distance to toilet facilities in covered and open mall buildings?
300 feet
What is the maximum travel distance to a drinking fountain in a covered or open mall?
300 feet
One what pages can you find all requirements for travel distances to plumbing fixtures?
Pages 27 - 28
In regards to water closets, urinals, lavatories and bidets, how close can these fixtures be set to adjacent fixtures?
30 inches center to center
Minimum distance of water closets, urinals, lavatories and bidets to any side wall, partition, vanity or other?
15 inches on center
What are the minimum dimensions for a floor mounted water closet compartment?
30 inches in width
60 inches in depth
What are the minimum dimensions for a wall hung water closet compartment?
30 inches in width
56 inches in depth
Is a water closet compartment required in a single-occupant toilet room?
No, as long as there is a lockable door.
Toilet rooms located in child day care facilities and containing _____ or more water closets shall be permitted to have one water closet without an enclosing compartment.
Two
For urinal partitions, the walls or partitions shall begin at a height not greater than _____(1) inches from and extend not less than ______(2) inches above the finished floor surface.
(1) 12 inches
(2) 60 inches
For urinal partitions, the walls or partitions shall extend from the wall surface at each side of the urinal not less than ______(1) inches or to a point not less than ______(2) inches beyond the outermost front lip of the urinal measured from the finished back-wall surface, whichever is greater.
(1) 18 inches
(2) 6 inches