Minimum thickness of lead on lead bends and traps?
1/8 inch
Minimum slope on 2-1/2 inch or less horizontal drainage pipe?
1/4 inch
Minimum slope on 3 to 6 inch horizontal drainage pipe?
1/8 inch
Minimum slope of 8 inch or larger horizontal drainage pipe?
1/16 inch
Horizontal branches shall connect to the bases of stacks at a point located not less than ______ times the diameter of the drainage stack downstream from the stack.
10
Lead wiped joints shall be fully wiped, with an exposed surface on each side of the joint not less than _______ inch.
3/4 inch
Lead wiped joints shall be not less than _____ inch thick at the thickest point.
3/8 inch
DFU value for bathroom group (1.6 gpf water closet)?
5 dfu
DFU value for bathroom group (greater than 1.6 gpf water closet)?
6 dfu
One clean-out is required for every _________________.
Four horizontal 45s