Formulas & Numbers Flashcards

1
Q

Annual General Public Exposure

A

0.5 rem / year
5 mSv / year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Annual Occupational Exposure

A

5 rem / year
50 mSv / year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Annual Radiograph Student Exposure <18

A

0.1 rem / year
1 mSv annually

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Lifetime Occupational Dose

A

1 rem x age in years
10 mSv x age in years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Annual Lens of Eye Dose

A

15 rem / year
150 mSv / year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Annual Skin / Hands & Feet Dose

A

50 rem / year
500 mSv / year

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Pregnant Worker Dose

A

.5 rem / gestation
5 mSv / gestation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

FETAL DOSE
- TOTAL
- MONTH

A

.5 rem / gestation
.5 mSv / gestation

.05 rem / month
.05 mSv / month

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  1. SID Accuracy:
  2. Collimation Accuracy:
  3. PBL Accuracy:
  4. Alignment Accuracy:
A
  1. 2%
  2. 2%
  3. 1-2%
  4. 1%
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Regular Apron Lead Equivalency
Minimum & Recommended

A

25 mm Pb Min.

0.5 mm Pb Rec.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Fluro Apron Lead Equivalency Minimum
Regular & Portable

A

Regular: 0.5 mm Pb min.
Portable: 0.25 mm Pb min.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Neck/Thyroid Lead Equivalency

A

0.5 mm Pb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Gloves Lead Equivalency

A

0.25 mm Pb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Eyeglasses Lead Equivalency

A

0.35 mm Pb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Fluro Drape Lead Equivalency
Minimum & Recommended

A

0.25 mm Pb min.
0.5 mm Pb rec.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Buckey Slot Cover Lead Equivalency
Minimum & Recommended

A

0.25 mm Pb min.
0.5 mm Pb rec.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Glass Window Lead Equivalency

A

1.5 mm Pb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Filtration
Inherit:
Total Below 50 kVp:
Total 50-70 kVp:
Total 70+ kVp:

A

0.5 mm Al
Below 50 kVp: 0.5 mm Al
50 - 70 kVp = 1.5 mm Al
70+ kVp = 2.5 mm Al

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

SSD Fixed X-Ray Minimum Distance:

A

12 inches
30 cm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

SSD Portable X-Ray Minimum Distance:

A

12 inches
30 cm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

SSD Fixed Fluro Minimum Distance:

A

15 in
38 cm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

SSD Portable Fluro Minimum Distance:

A

12 in
30 cm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

X-Ray Collimator to Skin Minimum Distance

A

6 in
15 cm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Portable Cord Length

A

2 Meters
6 Ft
72 in
180 cm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Scatter Intensity
1/1000 .001 or .1% OF PRIMARY BEAM AT RIGHT ANGLE & 1 METER FROM PATIENT
26
Maximum Tabletop Exposure Rate in Fluro
10R / min @ 1 meter
27
Maximum Leakage Radiation From Tube Housing
100 mR / hour @ 1 meter 1 mGy / hour @ 1 meter
28
Primary Barrier Lead Equivalent
1/16in .16 cm 1.6 mm
29
Secondary Barrier Barrier Lead Equivalent
1/32 in .08 cm .8 mm
30
Overlap of Primary & Secondary Barriers
1/2 in 1.25 cm
31
Image Intensifier Lead Equivalency
2 mm
32
Hematopoietic Dose
1 - 10 Gy within 3-6 weeks
33
Gastrointestinal Dose
>6 - 50 Gy within 1 week
34
Cerebrovascular Dose
>50 Gy within hours/days
35
Q.F.: X-RAY: GAMMA: BETA: ALPHA: FAST NEUTRONS:
X-RAY: 1 GAMMA: 1 BETA: 1 ALPHA: 20 FAST NEUTRONS: 10
36
Mitotic Delay Dose
.01 Gy 10 mGy
37
Instant Death Dose
1000 Gy in seconds
38
Reproductive Death Dose
1 - 10 Gy
39
Blood Change Dose
.25 Sv 25 rem
40
Erythema Dose Range
2.0 - 6.0 Sv 200 - 600 rem
41
Temporary Sterility Dose
2.5 Sv 250 rem
42
Doses For: LD 50/30: LD 50/60: LD 100:
LD 50/30: 300 rad (3.0 Gy) LD 50/60: 350 rad (3.5 Gy) LD 100: 1000 rad (10 Gy)
43
Sublethal Dose Range
200-300 rad 2-3 Gy
44
Superlethal Dose Range
600 - 1000 rad 6-10 Gy
45
Reduction in Sperm Count & Suppressed Menstruation Dose
10 rad .1 Gy 100 mGy
46
Temporary Sterility in Gonads
200-250 rad 2 - 2.5 Gy
47
Permanent Sterility in Testes & Gonads
500 - 600 rad 5 - 6 Gy
48
Cataract Formation Dose - Single - Fractional
Single: 200 rad / 2 Gy Fraction: 1000 rad / 10 Gy
49
Preimplantation Embryonic Death Dose
.05 - .15 Gy 5 - 15 rad
50
Second & Third Trimester Embryo Death Dose
>200 mSv
51
NRCP Report #105
Radiation Protection for Personnel
52
NRCP Report #102
Exposure Reduction, Filtration & Shielding Requirements
53
NRCP Report #147
Barrier Thickness
54
Roentgen (R) to Coulombs /kg Coulombs /kg to Roentgen (R)
55
RAD to Gray (Gy) Gray (Gy) to RAD
56
REM to Sievert (Sv) Sievert (Sv) to REM
57
Conventional / Traditional Units Are:
Roentgen (R) = Exposure Air rad = Radiation Absorbed Dose rem = Radiation Equivalency / Biological Dose Curie (Ci) = Radioactivity
58
SI Units Are:
Coulombs/Kg (C/kg) = Exposure Air Gray (Gy) = Radiation Absorbed Dose Sievert (Sv) = Radiation Equivalency / Biological Dose Becquerel (Bq) = Radioactivity
59
Sieverts to Millisieverts
- # of Sieverts x 1000 = mSv
60
Millisieverts to Sieverts
- # of millisieverts x .001
61
Formula for Maximum Electrons In Orbital Shell
2n^2
62
Centi = Milli =
Centi: 1/100 or .01 Milli: 1/1000 or .001
63
Power Formula
P = IV
64
Ohms Formula
V - IR
65
Step-Up Transformer A. Turns Ratio B. Voltage Increase:
A. 700:1 B. 500-1000 *Converts V to KV
66
Step-Down Transformer Voltage
8 - 12 V
67
Voltage & Turns Ratio Formula
68
Ripple Effect & Efficiency: A. Single Phase: B. Three Phase (6p): C. Three Phase (12p): D. High Frequency:
*MINUS RIPPLE FACTOR FROM 100 = EFFICIENCY