Honeywell Titan Flashcards
(26 cards)
The respirator should not be used beyond ___after initial exposure to chemical warfare agents to avoid the pos- sibility of agent permeation.
6 hours
Honeywell warrants this product to be free from defects in materials and workmanship for ___ from the date of purchase, with the exception of the compressed air cylinder
12 years
the standard cylinder is warranted for ___ years
15
the extended life cylinder is warranted for ___ years
30
the first stage pressure reducer, which is warranted for the ___ of the product
life
The electronics for the Heads-Up Display (HUD), battery pack, PASS, and pressure transducer are warranted for ___ years.
5
This SCBA is designed for storage in temperatures from____. If stored below 0° F, the SCBA must be warmed to above 0° F before use.
-25° F to +160° F
The backpack consists of a ____ backplate with an aluminum hip plate that both swivels and hinges on the backplate.
lightweight aluminum
The air cylinder is of composite construction with an aluminum inner liner overwrapped by carbon fiber, and has a maximum working pressure of ___.
4500 psig
The first stage pressure reducer lowers cylinder
air pressure to a nominal ___.
115 psig
The relief valve activates to protect the system when the intermediate pressure exceeds ___
200 to 225 psig.
The low pressure SCBA audible alarm activates at ___ psig (2216 psi system)
731 to 820
the high pressure SCBA audible alarm activates at ___ psig (4500 psig systems).
1485 to 1665
The audible alarm will continue to sound until the air pressure drops below ___.
200 psig
If the low battery alert activates (amber LEDs on the front and back PASS flashing every ___) during storage, the batteries must be replaced before using the SCBA.
ten seconds
The display consists of four green LEDs, representing____
Full, 3⁄4, 1⁄2, and 1⁄3
When the pressure drops below 50% of cylinder capacity, the LED representing 1⁄2 cylinder capacity starts to flash, and continues to flash for a short time (____) before returning to being continuously lit.
approximately 20 seconds
When the pressure drops to 1⁄3 (33%) of cylinder ca- pacity, the last green LED ____, giving the user a visual low pressure alarm in addition to the audible alarm located at the upper left of the backpack.
turns red and begins to flash
on a 4500 psig SCBA, the 1/3 LED will turn red and begin to flash between ____ psig
1485 and 1665
When the pressure drops to ___ of cylinder capacity, the red LED begins flashing noticeably faster and continues until air pres- sure drops below approximately 200 psig, at which time the display will turn off.
10%
An ____ LED, mounted on the front of the HUD module, warns others of the user’s low air status by flashing at the same time the 1⁄3 LED is flashing inside the HUD module.
external red
The external red LED flashes ___ when the pressure drops to 10% of the cylinder capacity. A red LED at the ___ of the backpack performs the same functions.
noticeably faster / lower right
An audible beep will also sound every ___ to indicate a low battery condition.
ten seconds
Prior to re-installing the battery cap, ensure that the cap ___ is not damaged.
O-ring