1
Q
Fumes, Smoke and/or Fire in Cockpit/Cabin
A
If severe - Land Immediately
ECS Master OFF
Crew fan OFF
Prepare Fire Ext
Ventilate cockpit and cabin
(Possible or Practicable)
2
Q
ROTOR DE-ICE
(RED)
A
Failure of RIPS
Check prevailing icing conditions
3
Q
AC ELEC FAIL
(RED)
A
Double AC Gen Fail
Check NR on CDS or ISIS
Start APU
AC BUs to SPLIT
ANTI ICE Rotor ON/OFF - OFF
Select ADS to off
Attempt reset main gen (2 attempts)
Check ELEC panel for success reset (not IDUs)
If unsuccessful - select failed generators to OFF
EMRG/NORM to EMRG
Re-engage ASE
(Possible or Practicable)