Low Rise Fire Proof MD’s Flashcards
(26 cards)
LRFPMD’s
Are generally ——— Buildings and may be found in proximity to ————.
1.1
Older buildings
High rise fire proof MDs
Low rise fireproof MDs.
Are usually how many stories?
1.2.1.
3-7 stories
Less than 75 feet
LRFPMD’s
Stairs shall be used when the fire is on ——- floor or below.
1.2.5
7th floor or less
LRFPMD’s
Who recalls the elevators whether or not they will be used?
Who ensures that all elevators are recalled and searched? 1.2.5.
1st Ladder
2nd Ladder
LRFPMD’s
Do these buildings have standpipe systems?
1.2.7
Usually not equipped with the standpipe systems
LRFPMD’s
Emphasis will generally be placed on
———— after approval Of the IC early in the operation. 1.4.
Venting the attack stair bulkhead
LRFPMD’s
The venting of the attack stairway will be accomplished by? 1.4.
1st and 2nd roof FF’s
LRFPMD’s
Isolated buildings with two stairways. The enclosed stairs are found remote from each other and roof access is generally via the? 2.3.1.
Enclosed Evacuation stairway
LRFPMD’s
What size line may be used If hose is hand stretched from a pumper? 3.1.
1 3/4 or 2 1/2
LRFPMD’s
When multiple stairways are available, the ——— ——— Should select the stairway that will provide the most efficient stretch and attack possible based on type of occupancy, existing conditions and communications with the Ladder officer. 3.2
Engine officer
LRFPMD’s
Who will assist in determining the attack stairway? 4.1.2 B 1A
Ladder Officer will asssist the Engine Officer.
PS Engine Officer shall notify the IC of the identity of the attack stairway.
This is very important information for the Roof firefighter to determine his way to the roof.
LRFPMD’S
T:F
Once the attack stair has been selected all operations are to proceed from the stairway in order to ensure evacuation stairway is maintained clear of smoke. 4.1.2 BB.
False
The only exception to this procedure is when the roof firefighters use the evacuation stairway to reach the roof.
LRFPMD’S
A 35 foot portable ladder often can be reached by what floor? 4.1.3 B2.
4th floor
LRFPMD’s
1st Ladder
If no outside operations are possible, then the —— and —— Team shall proceed to the fire floor to team up with their officer and assist in the search of the fire floor hallway and fire apartment.
4.1.3 B4
OV/Chauffeur
LRFPMD’s
1st Due Truck Roof FF
What tools?
4.1.4
Halligan Hook, Halligan,
LSR and lifebelt
The same tools for 2nd Roof the exception is Top Floor fire bring KO in lieu of LSR and Life Belt
LRFPMD’s
What is the priority order for roof access? 4.1.4 B2
Stairway in the attached adjoining building.
Enclosed evacuation stairway.
Aerial ladder or Tower ladder
LRFPMD’s
Roof ventilation must not occur until order by? 4.1.4 note page 6.
IC
LRFPMD’s
There are a few isolated buildings that exist, where there’s only one open interior stairway to the roof, and the roof cannot be accessed via Aerial or Tower ladder. A decision must be made by the company officer as to whether or not Roof vent is required. If the stairway is not an IDLH and safety permits, the Roof fire fighter, maybe ordered to take the interior stair to the roof, provided that the fire apartment door is controlled by the Ladder company officer. If the stairway is an IDLH then roof firefighters must be teamed up with another member before ascending to the roof. In either case, the fire apartment door must be maintained closed until the Roof firefighter has communicated to the their officer that they are on the roof and in a safe area, and the bulkhead door is closed. If ordered by the IC provide vent of the stairway bulkhead. The Roof fire fighter remain on the roof until the fire is ———— and the interior stairway is Safe to descend.
Note page 7.
Under control
**LRFPMD’S
Who is responsible to take the K0 curtain? 4.2.1 A
2nd Ladder
Officer and forcible entry team
LRFPMD’S
Which unit is responsible for all floors and stairs above the fire floor? 4.2.1 B1.
2nd ladder company
LRFPMD’s
Top floor fire second new truck will coordinate vent and entry in search of fire floor with first ladder company. Who will bring the cable curtain to the roof? 4.2.1. 4
2nd ladder roof firefighter will bring the KO curtain to the roof
LRFPMD’s
2nd Roof firefighter tools?
Tools for top floor fire?
4.2.3
Halligan Hook, Halligan, LSR, and Lifebelt
Halligan Hook,Halligan , KO curtain
LRFPMD’s
Where is the first option for life-saving rope rescue in this type of building? 7.1.1
Operate from the roof if practical
LRFPMD’s
Roof rope rescue option number 1 is unavailable. If the 2nd Roof firefighter has not already reached the roof, 1st Roof FF should be directed to the apartment directly above the fire apartment. The 2nd roof FF shall bring their assigned tools, including the LSR to an apartment directly above the fire apartment. Buildings with two enclosed stairs, the second Roof fire fighter may descend the ———- to the apartment directly above the fire apartment. 7.1.2.
Evacuation stairway