Raft inspections LRU -25
- visual inspect every 6 months
- leak check 2.0psi
- 15 min stab
- 1hr leak test on boarding and support tube
- 2hr leak test on upper and lower tube
- 60 second to inflate fully on functional
- functional every 36 months or every 3rd leak test
- shop air 40psi
- after packing allow to sit min 1 hour max 72 hours
- leak test every 360 days
CGTO PG-85-00-310-A 2-31
Raft bottle specs
- hydro date 3 years M13520.1C
- torque seal in 2 places: F900 swivel junction on Y-fitting and inflation valve bottle/body junction point.
- pressure in bottle 3160 psi+- 100psi at 70 F +- 5 F
- CO2- 2.5lbs in cyl. after it should be 2.2+- .01 lbs record weight
- fill nitrogen to 3300-3400psi do not exceed 3400psi
- after 3 hr cooling period 3160+- psi
M13520.1C 2-15,16
How much pull force is required to actuate the inflation valve both rafts
6-15 lbs
CGTO PG-85-00-310-A 2-32
What is the normal and overload capacities
Normal- 6 persons
Overload- 9 persons
M13520.1C 2-13
How many pounds of CO2 can pass through the purifier cartridges before they shall be replaced
250 lbs
M13520.1C 2-16
What are the normal and overload capacities for the LRU-33 raft
Normal- 20 persons
Overload- 30 persons
13520.1C 2-5
What do the C-130J and H use for wing installation cable assembly for the LRU-33
C-130J- left wing: red color code right wing: green
C-130H- left wing: red/white right wing:green/white
13520.1C 2-5
How much pull force is required to actuate the inflation valve
6-15 lbs
CGTO PG-85-00-310-A 2-32
What is the normal and overload capacities
Normal- 6 persons
Overload- 9 persons
M13520.1C 2-13
How many pounds of CO2 can pass through the purifier cartridges before they shall be replaced
250 lbs
M13520.1C 2-16
What do you cover up with black pen in the rectangle on the LRU 25 raft container
over load capacity 9 persons and rotary wing
MPC 256204.0 p. 7
What is a caution when removing the Liferaft from the container
Inadvertent inflation
MPC 256204.0 p. 7
What size wrench is used to unscrew the chain connector attached to the inflation lanyard
7 mm
MPC 256204.0 p. 8
What is wrapped on the inflation hose attachment points on the inflation assembly discharge y fitting
black electrical tape
MPC 256204.0 p. 8
What do you apply to the swivel junction point on the inflation assembly discharge Y fitting and the inflation valve bottle fitting/body junction point
Thin bead of Torque seal F-900
MPC 256204.0 p. 8
Where do you place the heaving ring for the LRU 25
On top of a Hank and on top of INFERIOR life line(blue color)
MPC 256204.0 p. 9
What do you apply to the lower half of the threads of the hand pump
Anaerobic single-component adhesive
Loctite 242 blue type 2
MPC 256204.0 p. 10
What do you tighten the topping off valve of the hand pump with
27 mm wrench
MPC 256204.0 p. 10
What do you attach to the survival items equipment retaining line
A locally manufactured streamer marked “tie to survival equipment bag” using a bowline
MPC 256204.0 p. 15
What do you secure the cylinder in while not attached to the life raft
Chain vise
MPC 256204.0 p. 8
How many inches of the survival equipment retaining line should be left in the survival equipment compartment
12 in
MPC 256204.0 p. 17
What can the shop air be regulated to temporarily to open the check valve in the inflation hose?
50 psig
MPC 256204.0 p. 26
What pressure should the opening pressure of the PRV valve not exceed
2.9 psi
MPC 256204.0 p. 26
What pressure should the PRV fully close
No less than 2.1 psi