H65 Floats Flashcards

1
Q

How long will aircraft float with floats deployed

A

4 minutes in sea state 2 with all 4 deployed with the water line below the cabin floor

The floating helicopter should remain stable enough to tow in conditions up to Sea State 5 and remain afloat, with the loss of one rear float or loss of one airbag in one of the forward floats, for at least 12 hours in Sea State 2

CGTO 1H-65-C p 1-86

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Altitude for inflation

Pressure altitude for water landings

A

9800ft

4900ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What size are the packing assist dowel rods

A

1/ in diameter- 41 in long applied between straps and bottom lip
2-1/2 in diameter- 20-1/2 in long between straps and upper lip

MPC 25011.0 p. 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the proper folds for the forward float

A

first fold 10in down top to bottom towards manifold over load curtain and manifold for forward float

Hold with weight bag

Next fold- 14 in

MPC 25011.0 p. 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Float Facts

A

record serial number prior to packing
inflate to shape in less than 2.5s /cylinders discharged in less than 4s
max float speed 90knots
structural repair allowed
approbal from ALC required but no need to submit SCHR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How do you protect the floats during inspection

A

locally fabricate a 13x13 ft canvas cover

MPC 25011.0 p. 8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Avoid eye or skin contact with what compound

A

leak test mil-l-25567c

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What type of compressed air shall be used to inflate bags

A

regulated 40 psi or below from a filtered source to ensure no oil or moisture are present

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

before packing what shall be recorded

A

serial numbers, manufacture date(not to exceed 9 years 6 months)

MPC 25011.0 p. 8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is applied to the float supply coupling caps

A

Loctite 242

MPC 25011.0 p. 9

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is used to remove plastic rivets

A

Mallet and 1/8 in drive punch

MPC 25011.0 p. 6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is done to the ends of the lacing cords for the forward float manifold

A

Melted or wrapped with black tape

MPC 25011.0 p. 9

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How many temporary straps are applied for forward float packing

A

04

MPC 25011.0 p. 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What size sail needle is used for lacing floats

A

No. 15 blunt

MPC 25011.0 p. 11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What type of spacer is used on the couplings when inflating bags

A

Teflon

MPC 25011.0 p. 13

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What size sail needle is used for lacing the lace envelope closure on the aft bags

A

No. 14

MPC 25011.0 p. 15

17
Q

What do you mark the aft float supply line with and at how many inches from supply bottle fitting is it placed

A

Electrical tape
14 in

MPC 25011.0 p. 15

18
Q

What tape is used for the metal fittings for the supply lines on the forward float

A

Duct tape

MPC 25011.0 p. 9

19
Q

How many folds for packing the aft float?

A

7 folds

Float manual p. 729 REV 11

20
Q

How quickly do the floats take shape when inflated

A

2.5 seconds
4 seconds to deplete the cylinders

CGTO 1H-65C-1 p 1-88

21
Q

What are the psi pressures for stabilization and inspect

A

Leak test inspect- 0.75 psi
Stabilization inspect- 3.48 psi
Leak test- 3.0 psi after 30 minutes
After 3 hour leak test- min pressure- 2.25 psi

MPC 25011.0 p. 8