Midterm Flashcards

(42 cards)

1
Q

A system which is not solidly earthed but is connected to earth through a current limiting impedance.

A

IT System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Is an iron core reactor connected between transformer neutral and ground. It is used for limiting the capacitance earth fault current which is flowing when the line ground fault occurs in the line.

A

Peterson Coil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A power system where neutral of a generator, power transformer or grounding transformer are directly connected to the ground through a conductor of negligible resistance and reactance

A

Solidly Grounded

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Key design elements for static dissipators based on point discharge theory includes (3)

A

a. Number of dissipator electrodes
b. Radius of the dissipator electrode
c. Dissipator construction material

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The most common source of lightning cloud form

A

Cumulonimbus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

It is also called earthing well

A

Inspection point

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The typical duration of a lightning flash is approximately

A

0.5 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

British design of lightning protection system is based on (3)

A

a. Rolling sphere method
b. Use of natural conductors
c. Protective angle or cone method

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The National Electrical Code recommends additional electrode if a resistance to ground greater than

A

25 ohms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Factors affecting earth resistivity includes except
a. Type of soil
b. Method of measurement
c. moisture content
d. temperature

A

Method of Measurement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A lightning flash is a constant source of

A

Current

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

An installation where an earth terminal is not provided by the electric supply company

A

TT System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

In the British standard, S1 refers to

A

Strike directly to the structure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Electric shock severity is determined by the following except
a. ambient temperature
b. length of time current flows
c. path of current through body
d. amount of current through body

A

Ambient Temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The minimum recommended thickness of stainless steel sheet considered as part of LPS is

A

0.50mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Basic test methods for earth resistance measurements include (3)

A

a. clamp-on test method
b. Dead earth method
c. Fall-of-potential method

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Improving earth resistance include (3)

A

a. treat the soil
b. use of multiple rods
c. lengthen the earth electrode in the earth

18
Q

A neutral conductor is usually colored

19
Q

The average peak current for the first impulse of lightning is

20
Q

The lightning protection system is required to (3)

A

a. Intercept the lightning strike
b. Conduct the lightning strike safely to ground
c. Disperse the strike safely in the earth

21
Q

The permanent joining of metallic parts to form an electrically conductive path that ensures electrical continuity and the capacity to conduct safely any current likely to be imposed

22
Q

This method of measuring earth resistance is best applied when a simple ground system with existing return path through multiple grounds is present

23
Q

The cone of protection is determined by

A

Both height of structure and storm cloud

24
Q

Most common form of lightning that account for 90% or more of the cloud-to-ground flashes worldwide is

25
The path followed by fault current as the result of a low impedance occurring between the phase conductor and earthed metal
Earth Fault Loop
26
Methods of designing the air termination network includes (3)
a. The rolling sphere b. The mesh design c. The protective angle design
27
The mesh design Types of LPS earthing systems includes (3)
a. Type A b. Type B c. Foundation earth electrodes
28
Refers to location where at risk of full lightning strike and the full lightning electromagnetic field
LPZ 0a
29
The most severe surges on the line are produced by _______.
Lightning
30
Lightning produces a _______ fronted wave.
steep
31
Transients on the power system due to current chopping are taken care of by _______.
resistance switching
32
Arcing ground can be prevented by _______.
earthing the neutral
33
The lightning currents range from 10 kA to about ___ kA.
90
34
For successful working of ground wire, the footing resistance of tower should be _____.
low
35
A surge diverter should be located ______ to the apparatus to be protected.
close
36
A 1/50 µs surge is _______harmful than 3/50 µs surge. Assume the same peak value.
more
37
The ______ lightning strokes are very rare on the power system.
direct
38
Most of the lightning strokes are due to _______ charged clouds.
negatively
39
The stroke A will always occur on ________.
tallest object
40
________ cannot protect the equipment from the travelling waves reaching the equipment.
Ground wires
41
In sub-stations, the most commonly used type of arrester is _______ arrester.
thyrite
42
Surge absorbers are used to _______ the steepness of wave front of the surge.
reduce